20/24
DAMAGE
CAUSES
SOLUTIONS
No flow of water
from tap
Exhausted battery (the led blinks) Replace the battery
Electrical problem
- Disconnect and reconnect the battery
- Check the connections and
- Damaged sensor: ask for
Filter is dirty Clean the sensor window
The water flows for
1 minute (without any
object in front of sensor)
finally stop
Light reflections on the sensor
- Remove the reflection sources
- Adjust the servey distance
The water remains open
over 1 min
Blocked solenoid valve / Ask for
The faucet opens /
closes independently
with no reason
It's been 24 hours since the last one Correct operation
Blocked solenoid valve Ask for
1
2
Dirty sensor Clean the sensor window
s
>1
min
s
1
min
damage sensor
Light reflections on the sensor
supply
- Remove the reflection sources
- Adjust the servey distance
the cable’s integrity
ON
OFF
It flows only hot
or cold water
Water in-lets inverted
Invert water in-lets
Only hot or cold
water flows,regardless
of the handle selected
Out-let flow reduced
Non-appropriate
temperature
regulation
Water betwwen handle
and body
-
Insufficient working pressure
-
Cartridge blocked or dirty
-
Outlet obstructed by dirt or
limestone
-
Cartridge blocked or dirty
-
Cartridge blocked
- Replace cartridge
-
Pressure check
- Replace cartridge
- Disassemble and clean aerator
- Replace cartridge
1
- Hot water temperature insufficient
- Check the system
- Filters in-lets obstructed by dirt and - Disassemble and clean filtres
limestone
Blocked solenoid valve Ask for
Electrical problem Disconnect and reconnect the battery
(RESET)