AUTOMATIC SOFTENERS INSTRUCTIONS MANUAL
A
M
/T A
M
/RT A
M
/V A
M
/RV A
M
/METER A
M
/R METER
s.r.l. - IT
ALY
Page 15 of 15
am_tv
m
_mi-r
1.
d
o
c
- r.1
follow
s
PROBLEM
CAUSE
HOW TO SOLVE
•
During regeneration the
unit
does
not draw brine
•
drain
line
of the softener clogged or, however of
too sm
all size
•
too low water pressure
•
drawing of air along the brine drawing line
•
injector
dirty
•
filter of injector dirty
•
brine float valve blocked or damaged
•
re-built correctly the drain line
•
increase the water pressure
•
check
the
connections
and the integrity of the
brine drawing tubing
•
clean the injector
•
clean the injector filter
•
clean or replace the brine float valve
•
There is a leakage of
water
to
drain
during service
•
internal pistons of the control valve blocked
•
O-ring of internal pistons spoiled
•
internal pistons spoiled
•
pilot pistons spoiled or broken
•
clean or replace the pistons
•
replace
O-rings
•
replace
pistons
•
replace pilot pistons
•
The unit does not feed treated water
•
regeneration does not run
•
brine is not drawn
•
a water failure occurred during regeneration
•
resins
spoiled
•
see
above
•
see
above
•
run regeneration again
•
replace
resins
•
The unit does not feed water
•
pistons blocked during regeneration
•
clean or replace the pistons
•
The
unit
feeds salted water after
regeneration
•
a water failure occurred during regeneration
•
the fast rinse time is too short
•
allow the water flowing until it is not salted
any
more
•
adjust a longer time of fast rinse
•
There
is
a
leakage of resins to the
drain or to outlet line
•
one (or more) filter nozzle of
distribution
system
is
damaged or broken
•
replace the nozzle