2.3    Autocompensation of the fluxgate compass

Please refer to the compass user manual before starting the autocompensation procedure.

In order to achieve a successful autocompensation, you must navigate :

-

  On smooth sea, with no current and no wind.

-

  Away from large magnetic masses such as cargo boats.

-

  In an open area allowing the execution of a circle with a diameter approximately 5 times the

length of the boat.

-

  At a constant speed of about 2 or 3 knots.

Procedure

1. Select the 

magn head 

channel,

2. Start to describe the circle, then press the 2 second on the key 

, to launch the

autocompensation procedure.

3. One single circle

*

 is sufficient to perform the autocompensation correctly, when its a

success, the  message 

3000

 is indicated.

For the previous generation of compass, referenced as 90-60-005, at least three circles
must be executed.

In case of problem during autocompensation, the 

SL50

 displays the 

PAN

 message , plus one

code :

-

  Code 1 : cancellation at user request.

-

  Code 2 : detection of a gyration in the opposite direction. Start again clockwise.

-

  Code 3 : excessive variation between 2 heading measurements. Reduce the speed of your

boat to 2 or 3 knots.

-

  Code 4 : angle correction higher than 20°. Start the autocompensation procedure over.

In case of autocompensation error, the measurements are not saved to the memory and the
sensor resumes its normal operating mode.

2.4 Technical specifications

-

  Power supply : 10 to 16VDC

-

  Consumption : 20mA without lighting and 70mA with lighting.

-

  Tightness : IP67

-

  Weight :  1.150kg including cable

-

  Dimensions : height = 260mm ; width = 156mm ; thickness = 45mm

-

  Operating temperature :  -10°C to +50°C

-

  Storage temperature :  -20°C to +60°C

-

  Horizontal viewing angle : superior to 120°

-

  Vertical viewing angle : superior to 90°

Height of the characters displayed : 50 mm for the channel, and 10 mm for the identifier and the
unit.

Содержание Multifunction SL50

Страница 1: ...Z I Kerandr Rue Gutenberg 56700 HENNEBONT FRANCE http www nke fr N indigo 0 892 680 656 0 34 min Multifunction SL50 and its remote control Product reference 90 60 445 white 90 60 472 carbon USER GUIDE...

Страница 2: ...LUXGATE COMPASS 14 1 12 ZERO SETTING OF THE DAILY LOG 11 1 13 CHOICE OF LANGUAGES 10 1 14 USE OF THE CHRONOMETER 12 1 15 TECHNICAL SPECIFICATIONS 14 1 16 VERSION AND ADDRESS NUMBER OF THE DISPLAY 15 1...

Страница 3: ...excellent readability and a wide angle of view of the data displayed whether by daylight or at night It is connected to the TOPLINE bus of your installation and displays all the channels available on...

Страница 4: ...ent in the following diagram is for information only and does not represent the equipment of your installation TOPLINE bus 20 61 001 GND DATA black 12VDC white Figure 1 log depth interface 90 60 450 l...

Страница 5: ...eated by the SL50 when set as master display Daily log Target speed Heading on other side NMEA Performance channels displayed Optimum wind angle Optimum VMG angle Optimum CMG angle Efficiency at close...

Страница 6: ...sure on this key also allows to set the level of lighting Mob Man Over Board key Press this key for 5 seconds and the function Man Over Board is activated When a speedometer and a compass are connecte...

Страница 7: ...hannel are the offset and the calibration coefficient setting parameters of the log speedometer sensor the measurement unit in knots or in km hr the filter setting the setting of the upper alarm and t...

Страница 8: ...alarms will allow you to supervise your TOPLINE installation effectively as well as the good operation of your boat Note that for angular channels such as magnetic heading or wind angle the sub channe...

Страница 9: ...ficantly it is useful to increase the filtering of the speed channel to stabilise the value displayed Conversely in calm sea low filtering will be preferable to obtain a fast response of the display F...

Страница 10: ...hannel Press Ent key to validate until the list of sub channels Valid alarm language and lighting appears Then successively press Ent key to select lighting Using keys and select green or red Press En...

Страница 11: ...nnels daily log and total log are at your disposal on your display You will use the daily log to count the number of nautical miles completed during a sailing leg The value is kept in memory when the...

Страница 12: ...tly at the start signal you can synchronise the chronometer countdown at T2 by pressing the Ent key During the procedure you can also return to the initialisation value by pressing the Ent key for 2 s...

Страница 13: ...and choose the OFFSET sub channel Note that this value is set to 0 1 2 Using the keys 3 4 Figure 4 Press The calibration is saved in memory Ent Then successively press to select the sub channel CALIB...

Страница 14: ...05 at least three circles must be executed In case of problem during autocompensation the SL50 displays the PAN message plus one code Code 1 cancellation at user request Code 2 detection of a gyration...

Страница 15: ...ate of the cables they must not show any sign of wear or cut The remote control does not control the SL50 The address of the remote control is lower than that of the SL50 reinitialise the remote contr...

Страница 16: ...TOPLINE bus and one NMEA input one user guide one protective cover four M4 fixing screws 3 2 List of accessories Standard terminal box TOPLINE bus 90 60 121 Terminal box TOPLINE bus with NMEA input 90...

Страница 17: ...as indicated on Figure 5 Clean the mounting surface with alcohol introduce the cable in the 18 drilled hole position the SL50 so that it faces the four 4 holes place the four screws provided with the...

Страница 18: ...18 SL50 User guide 33 60 022 000 Figure 5...

Страница 19: ...trip and galvanise the wires before connecting them inside the terminal box 3 7 Identification of the cable wires White cable 6 wires Wire identification White wire 12V Black wire Topline Data Braid E...

Страница 20: ...red wire from the init terminal GND power up your installation the SL50 then performs an auto test when the message connect the red wire appears reconnect the red wire on init GND the SL50 takes an ad...

Страница 21: ...____________________________________________________________________ _____________________________________________________________________________________________________ _____________________________...

Страница 22: ...____________________________________________________________________ _____________________________________________________________________________________________________ _____________________________...

Страница 23: ...____________________________________________________________________ _____________________________________________________________________________________________________ _____________________________...

Отзывы: