6
Pan Head Screw M5×10
Dust Catcher
Dust Box
Head
Fig.2
5. HOW TO OPERATE THE TOOL
WARNING
●
Always wear suitable eye protection, suitable
hearing protection, protective gloves, and
respiratory protective equipment.
5-1. Start and Stop
CAUTION
●
Always be sure the unit is in the OFF position
before plugging the power cord into an outlet.
To start, slide the switch forward while pushing down
it. (Fig.3)
To stop, slide back the switch. (Fig.3)
OFF
②Push
①Slide
①Push
ON
Fig.3
5-2. How to Adjust Chamfering Levels
WARNING
●
Be sure to turn the switch OFF and remove
the power plug from power supply whenever
adjusting chamfering levels.
●
The max. chamfering capacity
Stainless Steel: Up to 3mm Chamfer
Mild Steel: Up to 7mm Chamfer
(1) Loosen the Clamp Lever. (Fig.4)
(2) Rotate the arrow mark of the Eccentric Ring to the
Scale to adjust chamfering levels for chamfering
amount required. (Fig.4)
(3) Tighten the Clamp Lever after the adjustment.
(Fig.4)
The level guide is only for reference. If accurate
chamfering is required, set the tool at a chamfering
level about 0.5 smaller than the desired one.
Try a test cut. Then adjust the tool for accurate
chamfering.
In the case of Mild Steel
You can select chamfering levels from 0mm to 7mm
Chamfer freely. The maximum chamfering capacity
for one-cut is 4mm Chamfer. For 4mm Chamfer to
7mm Chamfer, chamfer a workpiece twice or three
times.
(Ex. 7mm Chamfer : 4mm Chamfer
→
5.5mm
Chamfer
→
7mm Chamfer Total 3 times)
In the case of Stainless Steel
You can select chamfering levels from 0mm to 3mm
Chamfer freely. Chamfer the desired volume at a
time without dividing the chamfering job to several
times.
Adapter
Clamp Lever
Chamfering
Levels
Eccentric Ring
Fig.4
5-3. Adjustment of Radius Chamfering in Amount
(1) Fix a radius chamfering Indexable Inserts.
(2) Loosen the Clamp Lever. (Fig.4)
(3) Rotate the arrow mark of the Eccentric Ring to the
scale of the Adapter to adjust chamfering levels
according to the size of the radius chamfering
Indexable Inserts.
(4) Tighten the Clamp Lever after the adjustment.
(5) Conduct a test cutting. Readjust the Clamp Lever,
so that sizes A and B become identical. (Fig.5)
A
B
R
Fig.5
5-4. How To Adjust Chamfering Angle
WARNING
●
Be sure to turn the switch OFF and remove