![Nilfisk-Advance SW700B Скачать руководство пользователя страница 9](http://html1.mh-extra.com/html/nilfisk-advance/sw700b/sw700b_operators-manual_1693363009.webp)
56041472(2)00-02
PREPARING A NEW MACHINE
2
- If the battery is set without acid solution it
must be filled up (density from 1,27 to 1,29
kg at 25°C) according to the instructions
contained in next paragraph.
BATTERIES FILLING UP WITH ACID SOLUTION
Please pay a strict attention when working
with sulphuric acid, as it corrosive. If it comes
in contact with the skin or the eyes, wash
abundantly with water and call a doctor.
Battery has to be filled up in a properly
ventilated area.
Fill up each element of the battery with acid;
the right level is roughly 10÷15 mm over the
electrodes.
After one hour fill up with acid if necessary.
Let battery rest for one hour and proceed
with the charging (please refer to the
paragraph “MAINTENANCE”). When carrying
out the recharge operation, all the caps of the
battery have to be open.
Warning! Before starting the recharge
operation, the connector of the battery must
be disconnected from the machine.
At the end of the recharge operation close all
the caps of the batteries, clean their upper
part and remove all possible acid remains.
Connect the battery’s connector to the
machine.
6