56041472(2)00-02
Warning: these operations must be carried
out with the machine off and the key
switched off. All periodic or extraordinary
maintenance operations must be performed
by skilled personnel, or by an authorised
service centre.
Note
: The battery life will depend on the level
or periodic maintenance (checking the
electrolyte level and density). If the machine
does not run for a long time (ex. 4 to 6 weeks)
it will be necessary to recharge the batteries
to make sure that their voltage does not go
under 10,5 Volt. Infact unused batteries get a
self-discharge.
SUMMARY TABLE
23
CONTROL
UPON
DELIVERY
EVERY
30/h
EVERY
50/h
EVERY
100/h
EVERY
500/h
Battery liquid level and
voltage
•
•
or every two
weeks
Check the carbon brushes of
all electric motor, and
replace them if worn-out.
•
Belt tightening
•
•
Filter shaker
•
Nut and screw tightening
•
Side and central brush
condition
•
Panel filter cleaning
•
Filter, gasket seal, flaps
•
•
Control devices cable adjust-
ment
•