27
SH TRUCK
Original Instructions
8 Technical
Data
Model
Pump pressure
1)
bar
175
180
85
Water volume, min./max. pres. l/min
21/19.5
16.1/15.5
14.1/13.3
Water tank, volume
liter
3
3
3
Water coonnection:
Max. pressure, feed water
bar
10
10
10
Min. pressure, feed water
bar
1,0
1,5
Max. temperature, feed water
°C
30
30
30
Spray lance:
Nozzle type, h. p./l.p.
0680
0550
0700
Thrust, max.
N/kp
49/4.9
43/4.3
25/2.5
Pipeline, max. length
m
Ø12 x 1.5 - max. 50
m
Ø15 x 1.5 - max. 180
m
Ø18 x 1.5 - max. 500
When using max. pipe length, only use a high pressure hose of 10 m.
Sound pressure level L
pA
measured in accordance with
ISO 11202 [DISTANCE 1m]
[FULL LOAD]:
dB(A)
76
75.5
71.5
1)
10 m (3/8") high pressure hose.
Data at 12°C hot feed water.
We reserve the right to make alterations.
9 Warranty
Your Nilfi sk product is guaranteed for 12 months from date of purchase (purchase receipt must be
presented) on the following conditions:
• that defects are attributable to fl aws or defects in materials or workmanship. (Usual wear and tear as
well as misuse are not covered by the guarantee).
• that repairs have not been carried out or attempted by other than Nilfi sk-trained service staff.
• that only original accessories have been applied.
• that the product has not been exposed to abuse such as knocks, bumps or frost.
• that the instructions in the manual have been carefully observed.
A warranty repair comprises the replacement of defective parts, but it does not cover freight and pack-
aging charges. Besides we refer to national Sale of Goods Act.
Any
illegitimate
guarantee repair will be invoiced. (I.e. malfunctions due to
causes
mentioned in sec-
tion
“7.0 Trouble shooting”
of the instruction manual).
SH TR
UCK
5M-180/970
SH TR
UCK
5M-85/850
SH TR
UCK
7P-175/1260
Содержание SH TRUCK
Страница 1: ...SH TRUCK Instructions for use 107319141 k 08 2015 EN DE FR NL ES IT RU PL HU...
Страница 57: ......
Страница 58: ......