3/13
A - 13
56091081 - SC8000
ENGLISH - A
INSTRUCTIONS FOR USE
INSTALL THE BRUSHES
CAUTION!
Turn the key switch off (O) and remove the key, before changing the brushes, and before opening any access panels.
1
Make sure the Scrub Deck is in the RAISED position, the Key Switch
(50)
is off (O) and the Parking Brake
(28)
is set.
2
See Figure 2.
Push down on the Side Skirt Latch
(12 or 32)
and swing the Skirt Assy
(A)
open as shown.
3
Lift up on Latch
(B)
, swing Lever
(C)
out and pull to open the Idler Assembly
(D)
.
4
Slide the Brush
(E)
into the housing, lift slightly, push and turn until it seats.
NOTE:
Figure 2
shows a closeup view
(F)
of the Brush Lugs
(G)
and the Brush
Drive Hub
(H)
.
5
Swing the Idler Assembly
(D)
closed while holding Lever
(C)
at a 90 degree angle to the Idler.
6
Once the Idler Assembly
(D)
is closed, push Lever
(C)
in until Latch
(B)
can be slid back down in front of it.
7
Push down on the Side Skirt Latch
(12 or 32)
, swing the Skirt Assy
(A)
closed and release the Latch.
NOTE:
Refer to this section when rotating (
fl
ipping end-to-end) brushes according to the maintenance schedule.
FIGURE 2