Recovery System
37
Service Manual – SC351
Removal and Installation
Vacuum System Motor Disassembly/Assembly
Disassembly
1 Remove the solution and recovery water tanks
2 Make sure that the battery connector is
disconnected
3 Disconnect the 2 electrical connectors (A) for the
motor (B)
4 Remove the acoustic insulation panel (C)
5 Remove the screws (D), recover the washers and
nuts
6 Remove the motor cover (E) and recover the
gasket (F)
7 Remove the motor (B) and the acoustic
insulation pipe (G)
8 Check the gasket (F) and the gasket (H) for
damage If necessary, replace
Assembly
9 Assemble the components in the reverse order of
disassembly and note the following:
◦
When installing the gasket (I) into the hous-
ing (J) turn it until the lower tooth (K) and
upper teeth (L) are as shown in the figure.
◦
Install the motor (B) with the power supply
contacts as shown in the figure (M).
K
A
B
D
E
B
I
I
J
H
G
D
F
C
B
M
L
L
P100792