ENGLISH
USER MANUAL
22
33015501(3)2008-02 A
RS 501
MACHINE STORAGE
If the machine is not going to be used for more than 30 days, proceed as follows:
Empty the dust control system water tanks according to the following procedure.
Prepare the machine, as shown in the After Machine Use paragraph.
Store the machine indoor, in a clean and dry place, protected from bad weather conditions and with the following values:
Temperature: +1°C to +50°C
Humidity: maximum 95%
Disconnect the negative connector from the battery (18, Fig. E).
Handle the diesel engine as shown in the relevant Manual.
WARNING!
When the machine is to be transported or stored at ambient temperatures below 0°C, check that water tanks are empty,
disassemble and drain the water fi lter housing.
FIRST PERIOD OF USE
After the fi rst period of use (fi rst 8 hours) it is necessary to perform the following procedures:
Check the fastening and connecting elements for proper tightening. Check the visible parts for integrity and leaks.
After the fi rst 50 working hours, perform checks and replacements shown in the Scheduled Maintenance Table.
MAINTENANCE
The lifespan of the machine and its maximum operating safety are ensured by correct and regular maintenance.
The following table provides the scheduled maintenance. The intervals shown may vary according to particular working conditions,
which are to be defi ned by the person in charge of the maintenance.
WARNING!
Maintenance procedures must be performed when the machine is off (ignition key removed).
Moreover, read carefully the instructions in Safety chapter before performing any maintenance procedure.
All scheduled or extraordinary maintenance procedures must be performed by qualifi ed personnel, or by an authorised Service
Center.
This Manual contains the Scheduled Maintenance Table and describes only the easiest and most common maintenance
procedures.
For other maintenance procedures contained in the Scheduled Maintenance Table or for extraordinary maintenance procedures see
the Service Manual that can be consulted at any Service Center.
SCHEDULED MAINTENANCE TABLE
Maintenance
Running-in
period (after the
fi rst 50 hours)
Every 10
hours or
before use
Every
200
hours
Every
600
hours
Every
1,200
hours
Every
2,400
hours
Long
periods
Engine oil level check
Engine air fi lter cleaning
Engine radiator fi n cleaning check
Engine coolant level check
Battery fl uid level check
Hydraulic system oil level and drain fi lter effi ciency check
Hydraulic system oil cooler fi n check and cleaning
Hopper, fi lter and suction hose cleaning, and gasket
check
Water nozzle and fi lter cleaning
Brake fl uid level check
Reverse gear buzzer operation check
1.
2.
3.
•
•
4.
5.