C9 High Motor
Temp. Compressor
1. Water supply valve not closed
1. Secure sufficient air supply to
the valve.
2. Contact your local service
technician.
C20 Low Sensor
Signal P-Pumptop
1. Pressure signal from pumptop sensor, out of range
1. Press “off” button
2. If error reoccurs, contact your
local service technician.
C21 Low Sensor
Signal T-Pumptop
1. Temparature signal from pumptop, sensor, out of range 1. Press “off” button
2. If error reoccurs, contact your
local service technician.
C22 Low Sensor
Signal P-Air
1. Pressure signal form inlet sensor, out of range
1. Press “off” button
2. If error reoccurs, contact your
local service technician.
C23 Low Sensor
Signal T-Air
1. Temperature signal from inlet sensor, out of range
1. Press “off” button
2. If error reoccurs, contact your
local service technician.
C25 Low Sensor
Signal flow
1. Signal from flow sensor, out of range
1. Press “off” button
2. If error reoccurs, contact your
local service technician.
C30 High Sensor
Signal P-Puumptop
1. Pressure signal from pumptop sensor, out of range
1. Press “off” button
2. If error reoccurs, contact your
local service technician.
C31 High Sensor
Signal T-Pumptop
1. Temperature signal from pumptop sensor, out of range 1. Press “off” button
2. If error reoccurs, contact your
local service technician.
C32 High Sensor
Signal P-air
1. Pressure signal from inlet sensor, out of range
1. Press “off” button
2. If error reoccurs, contact your
local service technician.
C33 High Sensor
Signal T-Air
1. Temperature signal from inlet sensor, out of range
1. Press “off” button
2. If error reoccurs, contact your
local service technician.
C35 High Sensor
Signal flow
1. Signal from flow sensor, out of range
1. Press “off” button
2. If error reoccurs, contact your
local service technician.
C40 Sensor Load
Pumptop Sensor
1. Supply voltage for pumptop sensor too low.
2. Pumptop sensor using too much current
1. Press “off” button
2. If error reoccurs, contact your
local service technician.
C41 Sensor Load
Air sensor
1. Supply voltage for inlet sensor too low
2. Inlet sensor using too much current
1. Press “off” button
2. If error reoccurs, contact your
local service technician.
C43 Sensor Load
Flow sensor
1. Supply voltage for flow sensor too low
2. Flow sensor using too much current
1. Press “off” button
2. If error reoccurs, contact your
local service technician.
Содержание Hybrid Typhoon
Страница 1: ...Hybrid Typhoon Directions for use Gebrauchsanweisung Mode d emploi Instrucciones de uso...
Страница 80: ......
Страница 84: ...1 22 3 8 20 18 17 16 11 15 13 14 12 10 5 6 4 7 9 23 19 21 24 110004549 Hybrid Typhoon 110001405...
Страница 86: ...8 2 4 5 6 1 3 7 110004550 Hybrid Typhoon...
Страница 88: ...Hybrid Typhoon 1 3 2 4 5 110004554...
Страница 90: ...17198_30 1 2 3 Hybrid Typhoon...
Страница 92: ...Hybrid Typhoon 110004551 1 2...
Страница 94: ...Hybrid Typhoon 1 2 3 4 9 8 7 6 5 10 7 8 12 11 13 110004548...
Страница 96: ...Hybrid Typhoon 110004552 1 2 3...
Страница 98: ...Installation 658 1435 1011 1107 110004599...
Страница 100: ...El diagram 110004767E...
Страница 101: ...El diagram...
Страница 102: ...El diagram...
Страница 103: ...110004775D El diagram...
Страница 104: ...El diagram...
Страница 105: ...El diagram...
Страница 107: ...Pump curve 25 bar 50 Hz...
Страница 109: ...Layout Hybrid MU...
Страница 111: ......