56043021
- 260, 32, 38, 320, 380
VACUUM SYSTEM
________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________
VACUUM MOTOR REMOVAL - 32, 38, 320, 380
1
Drain the solution and recovery tanks and tip them to the sides of the machine.
2
Disconnect the batteries and open the front access door.
3
Remove the large equalizer spring (take note of which hole it is hooked in before removing).
4
See Figure 6. Remove access panel “G”.
FIGURE 6
G
H
Front
5
Disconnect the vacuum motor(s) that you are removing from the wiring harness.
6
Remove the (3) “H” screws and spacers and remove the vacuum motor from the machine.
7
Reassemble in reverse order and test for proper operation.