56043021
- 260, 32, 38, 320, 380
SOLUTION SYSTEM
________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________
SOLUTION CABLE REPLACEMENT - 260
1
Drain the solution and recovery tanks.
2
Tip the solution tank forward and remove the recovery tank from the machine.
3
Remove the vacuum motor hose for easier access.
4
See Figure 3. Disconnect solution cable “J” from the solution valve arm.
5
Remove the solution cable from the chassis mount (take note of its location in the mount).
6
Remove the control handle panel.
7
Remove the solution cable from the handle mount (take note of its location in the mount).
8
Disconnect solution cable “J” from the solution lever.
9
Pull the cable out through the back of the control handle.
10
Reassemble in reverse order and test for proper operation.