WSS100 - WST100
09/2014
6
GB
Controls, indicators and connections
Figure 4
1
ON/OFF switches of the vacuum units
2
Flow deviation valve control (WS...100DV models)
Inspection prior to starting
Figure 5
1
Inlet
Prior to starting, check that:
■ All latches are tightly locked;
■ The vacuum hose and tools have been correctly fitted
into the inlet (
1
);
■ The shaving container (optional) is installed, if applicable.
■ The liquid container is not full.
■ The float inside the liquid container is present and
correctly installed.
Starting up
Figure 6
1
Castor brakes
Lock the castor brakes before starting the vacuum cleaner (
1
).
Starting the vacuum cleaner
■ Push one of the switches or both of them (
1
- figure 4) to
start the vacuum cleaner. The related warning lights turn
on.
Stopping - Emergency stopping
■ Push the switches (
1
- figure 4) once again to stop the
vacuum cleaner.
Liquid vacuum stopping (fig. 1)
■ When the tank is full, the float (
11
) stops the vacuuming
operation; nevertheless, the vacuum units (
5
) remain
activated.
■ Switch off the vacuum units by pushing the switches (
3
).
Emptying the containers
Figure 7
1
ON/OFF switches of the vacuum units
2
Flow deviation valve control (WS...100DV models)
3
Liquid exhaust valve
Emptying the liquid container
■ Open the exhaust valve (
3
) after putting a container in
the position where the liquid will be discharged.
■ After emptying it, close the exhaust valve (
3
).
Emptying the liquid container with the flow
deviation valve (WS...100DV models)
■ Open the exhaust valve (
3
) after putting a container or
the drain hose (optional) in the position where the liquid
will be discharged.
N.B. Drain by gravity the liquid left inside the suction
hose.
■ Activate the deviation valve (
2
), and take it to A position,
in order to invert the vacuum flow.
■ Push both switches (
1
) to start draining, holding the drain
hose (
4
) firmly to prevent liquid splashes and leaks.
■ At the end of the emptying operation push both switches
(
1
) to stop the vacuum units.
■ To start the vacuum operation, close the exhaust valve
(
3
), take the valve (
2
) to
B
position, then push both
switches (
1
).
WARNING!
Do not operate on the deviation valve “2” when the
vacuum units are activated.
If the flow is inverted when the vacuum units are
activated, the machine may be damaged.
■ For more thoroughly cleaning the container, it can be
removed with the nuts under the buffers (
6
).
Содержание CFM WSS 100
Страница 2: ......
Страница 53: ...WSS100 WST100 1 09 2014 1 2 3 1 3 6 2 8 7 4 9 10 5 5 11 A B C B B WSS100 WST100 WST100 WSS100 A C 2 1 4 ...
Страница 54: ...09 2014 2 WSS100 WST100 7 5 8 1 6 1 A B 3 1 2 1 2 2 WST100 WSS100 5 6 4 3 4 3 ...
Страница 55: ...WSS100 WST100 3 09 2014 9 11 12 1 3 4 2 1 2 1 3 10 2 1 1 3 2 13 ...
Страница 56: ...09 2014 4 WSS100 WST100 14 1 2 2 6 3 4 5 7 5 4 3 6 2 2 1 ...
Страница 58: ...09 2014 6 WSS100 WST100 ...
Страница 59: ......