12
- FORM NO. 56043025 / BA 700, 800, 1000 / 28LX, 32LX, 38LX / 280HD, 320HD, 380HD
SOLUTION SYSTEM
FIGURE 2
7
Follow steps 1 - 5 in reverse order to reassemble. Make sure that the valve mount is in the forward two holes as shown.
8
Check for leaks and proper operation.
______________________________________________________________________________________________
FLOW CONTROL VALVE REPLACEMENT - BA 800, 1000 / 32, 38LX / 320, 380HD
1
Drain the solution tank at a designated “DISPOSAL SITE”.
2
Remove the left splash guard.
3
See Figure 2. Remove the
(E)
,
(F)
, and
(G)
Hoses from the solution valve fittings and mark them to ensure proper
reassembly.
4
Remove Ball Joint
(H)
from the valve
arm. Be careful not to lose the
bushings.
5
Remove the valve mounting bolts
and remove the valve from the ma-
chine.
6
Remove the fittings from the old
valve and remove the valve from
the mount, (note the positioning of
the fittings for reassembly).
7
Install the new valve on the mount
and install the fittings.
8
Follow steps 1 - 5 in reverse order to
reassemble.
9
Check for leaks and proper opera-
tion.
_____________________________________________________________________________________________________________________________
FLOW CONTROL VALVE REPLACEMENT - BA 700 / 28LX / 280HD (continued)