Control System
52
Service Manual – SC6500
™
Display
Code
Error/Fault Description
Correction
41
Back-up alarm open
1.
Use an ohmmeter to check for an open circuit in the
H1
back-up alarm and its wiring (wire colors ORN/
BRN and BLU/WHT). If defective, repair or replace.
2.
Test for 36V at the back-up alarm. If 0 Volts, check the
A2 control board assembly.
42
Back-up alarm short to ground
1.
The Back-up alarm and/or its +36V power feed is
shorted to ground. Test the positive wire to ground
for short circuit* (wire colors ORN/BRN b and
BLU/WHT battery -). Repair or replace the defective
wiring.
2. Disconnect the alarm and test to see if the circuit
wiring is still causing an error code (shorted). If not,
replace the back-up alarm.
* Short Circuit definition:
• A short circuit is a parallel path of very low resistance, often caused accidentally.
• With low resistance there is an excessive amount of current.
• The excessive current will either melt the wires or open a fusible link.
** See
Service Test Mode
in this manual for further troubleshooting information.
*** See the
Main Control Programming Options
section to activate the Brush Type Selection function.
Содержание 56414010
Страница 32: ...Chassis System 32 Service Manual SC6500 Chassis System Major Chassis Components 45 in 48in 1300mm models only ...
Страница 87: ...Options and Accessories 87 Service Manual SC6500 Description Warning Beacon Back Up Alarm Overhead Guard ...
Страница 138: ...Scrub System Disc 138 Service Manual SC6500 Special Tools Actuator Power Cord Adapter p n 56407502 ...
Страница 175: ...Sweep System Side Broom 175 Service Manual SC6500 Special Tools Actuator Power Cord Adapter p n 56407502 ...