Solution System
152
Service Manual – SC6500
™
Removal and Installation
Warning! Before removing or reinstalling any machine components, make sure the key switch
is off, the key is removed from the machine and the parking brake is engaged.
Solution Control Pump
Note:
Access the solution control pump
from underneath the machine.
1. Drain the solution tank or turn the solution
shutoff valve to the off position to prevent
solution loss.
2.
Disconnect the battery from the machine.
Note:
Place a suitable container
underneath the solution control
pump to catch any solution that
may leak from the pump or hoses.
3. Disconnect the pump
Electrical Connector
from
the machine harness.
4. Remove the four
#10-24 Screws
, Nyloc
™
nuts and flat washers holding the
Solution Control Pump
to the
bottom of the machine.
5. Loosen the
Clamps
holding the
Hoses
to the
Elbows
and disconnect (pry) the
Hoses
off of the
Elbows
.
6. Remove the
Solution Control Pump
from the machine.
7. Reinstall the
Solution Control Pump
by following the above steps in reverse order.
Solution
Control
Pump
Electrical
Connector
#10-24
Screw (4)
Clamp (2)
Hose (2)
Elbow (2)
Содержание 56414010
Страница 32: ...Chassis System 32 Service Manual SC6500 Chassis System Major Chassis Components 45 in 48in 1300mm models only ...
Страница 87: ...Options and Accessories 87 Service Manual SC6500 Description Warning Beacon Back Up Alarm Overhead Guard ...
Страница 138: ...Scrub System Disc 138 Service Manual SC6500 Special Tools Actuator Power Cord Adapter p n 56407502 ...
Страница 175: ...Sweep System Side Broom 175 Service Manual SC6500 Special Tools Actuator Power Cord Adapter p n 56407502 ...