INFORMATION MENU DISPLAY - CONTINUED
Menu Level
Notes
1
2
3
Options
User selectable options
Solution
Proportional*
Fixed
UK
Solution mode; Proportional – solution
fl
ow
increases with speed of machine. Fixed – Solution
fl
ow stays the same despite machine speed. UK
(United Kingdom) – solution
fl
ow is reduced to
conserve water.
Solution In Rev
No*
Yes
Leave solution on in reverse?
Lock Detergent
No*
Yes
Lockout detergent percentage adjustment for user?
Headlight
On*
Off
Headlight on/off at startup
Burst Of Power (s)
min = 60*
max = 300
step = 60
Burst-of-power (BOP) time span (seconds) EcoFlex
Fwd Speed Max (%)
min = 50
max = 100*
step = 10
Maximum forward speed as percentage of maximum
available speed
Lock Speed Limit
No*
Yes
Lockout scrub speed limit for user?
Inactivity Time (min)
min = 1
max = 30
step = 1
default = 15
Inactivity time before putting machine in sleep mode
(minutes)
Impact Detect
Off*
Log
Lockout
Impact detection status
Log – Impact is recorded
Lockout – Impact is recorded and User is locked
out of scrub functions (Display shows
(C26)
) until
machine is reset with a Supervisor key.
Impact Level
High*
Low
Impact detection sensitivity level. If nuisance
tripping occurs (i.e. driving over a
fl
oor transition),
adjust setting to low.
System
Firmware
Display current
fi
rmware revision
Serial Num
Display PCB serial number from factory
Impact Log
Display list of impact events with max value,
timestamp and user id (only if enabled)
- single item view will show max values for each axis
(x,y,z)
*Default setting
4/2016
A - 11
56091168 - SC6000
ENGLISH - A
INSTRUCTIONS FOR USE