Bypass operation
AUTO
>2<19°C
ENTER
VENTILAT
HIGH ”2”
ENTER
ENTER
VENTILAT
HIGH 2
COOLING
1
1. VENTILAT HIGH "2"
Select between levels 2, 3, 4 and OFF.
The
COOLING
menu allows selection of the unit automatically running at a higher/highest ventilation
level for low bypass mode.
Bypass operation is used when there is no need for heat recovery.
Cooling
2
TEMP
SET +5°C
TEMP
SET ”+5°C”
VENTILAT
HIGH ”OFF”
ENTER
ENTER
VENTILAT
HIGH OFF
ENTER
C
OOLING
1
1. TEMP "SET +5°C"
Indicates when refrigeration via compressor operation must be activated
in relation to the set room temperature. The value can be set to +1, +2, +3,
+4, +7, +10°C and OFF.
1. VENTILAT HIGH "OFF"
Here it is possible to chose high ventilation step when cooling. The value
can be set to: 2, 3, 4 and OFF.
In the
COOLING
menu it is possible to cool the air with active cooling via compressor operation.
Combi 302 Polar Top (English)
BY NILAN
19