Total Station DTM-322 Instruction Manual
133
Checking and Adjustment
6
Checking and Adjusting the Optical Plummet
The optical axis of the plummet must be aligned with the vertical axis of the
instrument.
To check and adjust the optical plummet:
1.
Place the instrument on the tripod. You do not have to level the instrument.
2.
Place a thick sheet of paper marked with an X on
the ground below the instrument.
While you are looking through the optical
plummet, adjust the leveling screws until the
image of the X is in the center of the reticle
mark .
3.
Rotate the alidade 180°.
If the marked image is in the same position
in the center of the reticle mark, no
adjustment is required.
4.
If the image is not in the same position,
adjust the optical plummet:
a.
Use the supplied hexagonal wrench to
turn the adjustment screws until the
image of the X is in Position P. Position
P is the center point of the line
connecting the X and the center of the
reticle mark
.
b.
Repeat from
.
Zero Point Errors of Vertical Scale and Horizontal Angle Corrections
Checking
1.
Set up the instrument on the tripod.
2.
Follow the leveling procedures described in
3.
Flip the telescope to the Face-1 position.
4.
Sight a target that is within 45° of the horizontal plane.
5.
Read the vertical angle from the VA1 field in the Basic Measurement Screen
(BMS).
P
Содержание Total Station DTM-322
Страница 1: ...www trimble com Total Station DTM 322 Instruction Manual Version A 1 0 0 Part Number C232E April 2009 ...
Страница 8: ...viii Total Station DTM 322 Instruction Manual ...
Страница 14: ...Contents xiv Total Station DTM 322 Instruction Manual ...
Страница 60: ...3 Getting Started 46 Total Station DTM 322 Instruction Manual ...
Страница 157: ...C H A P T E R 8 Total Station DTM 322 Instruction Manual 143 System Diagrams 8 In this chapter System Components ...
Страница 160: ...8 System Diagrams 146 Total Station DTM 322 Instruction Manual ...
Страница 176: ...9 Communications 162 Total Station DTM 322 Instruction Manual ...