JAA78851-R.3617.A
- L49 ・ AF-S DX17-55/2.8G -
●AF-S zoom DX17-55/2.8G inspection program
(1)
Menu display
・
Menu items
The items 1 and 2 are used for adjustments.
The item 3 is used for reading and writing EEPROM DATA.
The items 4~7 are used for inspections.
・
Selection items
After selecting any item, one of the lens selection display, the focal length selection display, the voltage setting,
display, the inspection start display, etc. appears. The displays are differrent depending on the items. Follow the
instructions of a personal computer.
・
Operating voltage
Power supply for AF motor
inside lens
Power supply for AF-I
communication box
Inspection of MR encoder operation
6.0 ± 0.1 V
Inspection of lens-servo stop accuracy
6.5 ± 0.1 V
5.5± 0.2 V
Inspection of lens-servo time
6.5± 0.1 V
Inspection of switches and lenses
6.0 ± 0.1V
・
Initial driving
When "WAIT FOR SOME SECONDS" appears, perform the initial driving (drive scanning five times and stop at
infinity-end).
1
2
3
4
5
6
7
INC
Содержание ED 17-55mm f/2.8G IF
Страница 75: ...JAA78851 R 3617 A L54 2 AF S DX17 55 2 8G Additional page November 4 2004 Target chart Resolution chart INC ...
Страница 83: ...JAA78851 R 3617 A F1 AF S DX17 55 2 8G 外観図 Sketch drawings 110 5 φ 85 5 INC ...
Страница 84: ...JAA78851 R 3617 A F2 AF S DX17 55 2 8G 組立図 Structure of the Lens INC ...