C H 1 = 5 V C H 2 = 5 V 5 m s / d i v
D C 1 0 : 1 D C 1 0 : 1
NORM 200KS/s
⑤
Confirm that the waveform on the oscilloscope has duty 50% and stop the MF ring at the close-end.
(Fig.1)
�
�
When the adjustment is completed, click "Next". (Fig.3)
⑥
Following the instruction on the screen, rotate the MF ring in the direction from "Close-end" to
"Infinity-end" slowly by hand.
Confirm that the waveform on the oscilloscope has duty 50% and stop the MF ring at
"
Infinity-end.
(Fig.2)
Fig.2
Fig.3
Fig.1
E terminal
H terminal
●
Oscilloscope setting
V/Div (CH1)
:
5V
V/Div (CH2)
:
5V
Coupling
:
DC
Time/Div
:
5m Sec
Trigger Mode
:
NORMAL
Trigger Coupling
:
DC
Trigger Source
:
CH
1
Trigger Position
:
+ 4 div
Trigger Type
:
EDGE
Trigger Level
:
2.5 V