![Nikon AF-S VR Zoom-Nikkor ED 24-120mm f/3.5-5.6G IF Скачать руководство пользователя страница 18](http://html1.mh-extra.com/html/nikon/af-s-vr-zoom-nikkor-ed-24-120mm-f-3-5-5-6g-if/af-s-vr-zoom-nikkor-ed-24-120mm-f-3-5-5-6g-if_repair-manual_1690555018.webp)
JAA78271-R.3598.A
- L16 ・ AF-S VR24-120/3.5-5.6G -
(GND)
( + )
・
Connections
Oscilloscope
(2ch)
Oscilloscope
(1ch)
Power supply
(+)
Power supply
(-)
Self-made tool
Oscilloscope
(2ch)
Power supply
Set values
5.0 V
100 mA
・
How to inspect and adjust
①
Make sure that the electric current and voltage of the connected rated voltage power supply are set to the set
values, and turn the power ON.
②
Set the oscilloscope and rotate the focus ring by hand.
Note
:
Because the waveform varies depending on the rotational speed of the focus ring, change the setting of Time/Div
properly.
③
In case wide waveform noise is seen, use the filter function.
How to set the filter function in case of Yokogawa-manufactured DL1540
1.
Press the filter button.
2.
Turn "Smooth" ON in the menu on the PC screen.
Standard
:
50mV or more of the amplitude of all waveforms
Note
:
Check the waveform by moving the focus ring back and forth from the infinity-end
position to the close distance end position.
Self-made tool
C H 1 = 2 0 m V C H 2 = 2 0 m V 5 m s / d i v
A C 1 0 : 1 A C 1 0 : 1
NORM 200KS/s
●
Oscilloscope
setting
V/Div (ch1)
:
20mV
V/Div (ch2)
:
20mV
Coupling
:
AC
Time/Div
:
5m
Sec
Trigger Mode
:
NORMAL
Trigger Coupling
:
AC
Trigger Source
:
CH1
Trigger Position
:
+4
div
Trigger Type
:
EDGE
Trigger Level
:
0V
INPUT (ch1)
:
AC
INPUT (ch2)
:
AC
INC
Содержание AF-S VR Zoom-Nikkor ED 24-120mm f/3.5-5.6G IF
Страница 8: ...JAA78271 R 3598 A L6 AF S VR24 120 3 5 5 6G 139 2 97 24 Zoom ring 89 3 89 3 DISTANCE SCALE RING INC ...
Страница 98: ...JAA78271 R 3598 A F1 AF S VR24 120 3 5 5 6G 外観図 Sketch drawings INC ...
Страница 99: ...JAA78271 R 3598 A F2 AF S VR24 120 3 5 5 6G 組立図 Structure of the Lens INC ...
Страница 100: ...JAA78271 R 3598 A F3 AF S VR24 120 3 5 5 6G INC ...