JAA79351-R.3670.A
- A17 ・ AF-S DX55-200/4-5.6G -
①
Mount the lens in the equipment (for center). (ref.
①
of (2) for how to fit in it.) Set the zoom ring to WIDE-
end (55 mm side).
(3) 4th lens group alignment (Center alignment)
②
Connect the VIDEO cable, which comes from the terminal of the CCD camera, and the fiber-optic cable,
which comes from MEGALIGHT 100, to the alignment equipment for center. Then rotate the LIGHT
CONT. knob of MEGALIGHT 100 to adjust the brightness so that the pinhole image appears on the
monitor. Also turn the lens focus ring to adjust the shape. (ref. Pic 1 for pinhole images.)
CCD camera
VIDEO cable
Fiber-optic cable
LIGHT CONT.knob
Pic.1
Focus ring
INC