EN
56
10-364
4.3. Overall picture of the device
1
Infrared receiver
5
Nameplate
2
Closing
6
Connection terminal
3
LED display
7
DIP switch
4
Flush-mounting position
8
ISP connection
4.4. Technical data
Power supply voltage
+24 V ± 8 % (power supply and control device)
18 to 28 V (for stand alone mode)
Input current in standby
3-wire operation: I(a) = I(a) = 0.1 mA, I(P) = 11 mA
Maximum input current
I(P
max
) = 25 mA
Housing
Acrylic glass, matt black
Dimensions (H x W x D)
105 x 105 x 26 mm
Weight (g)
200 g
Allowable ambient temperature
-25°C … +55°C
Protection degree
IP44
RFID technology
MIFARE Classic®, carrier frequency 13.56 MHz
Relay contact
Two-way switch, 24 V AC / DC / 2 A
Infrared remote control
Carrier frequency
37.9 KHz ± 125 Hz
Signal range
At least 1 m in open spaces (15° deviation from direction at a distance of 3 m)
Operating temperature
-10°C to + 50°C
Storage temperature
-20 to +60 °C
Battery
Key cells CR2025 (DC 3.0 V)