irrespective of the current load condition, and for as long as the contact
remains closed.
When the panic function is activated, the load is set to its maximum
value (=100%). Upon deactivation, the load returns to the condition prior
to activation. The panic button function works in each control mode,
but not if the analog control is in programming mode.
C. Meaning of LEDs during normal operation
Control mode LEDs
You can choose from 3 control modes: 0-10V analog control, 1-button
control or 2-button control. The control mode LEDs indicate which
control mode has been selected.
During
normal operation
, the control mode LEDs have the following
meaning:
LED status meaning
current mode of operation: 0-10V analogue control
current mode of operation: single push button control
current mode of operation: double push button control
If the lighting is switched on, the load LED lights.
EN