60
05-711
B. Setting minimum ‘min’
In programming mode, to go from ‘input’ to ‘min’, briefly press the
programming button. The load dims up/down to the set minimum.
You can set the dimming intensity in the section ‘min’ to a value
between 1% and 40%.
Proceed as follows (see next diagram):
- Place the analog control in the section ‘min’ of the programming
mode: LED ‘min’ blinks.
- Set the desired min. intensity using the ‘select’ button or the connected
control. Keep the button pressed to dim up to 40% or down to 1%. To
reverse the dimming direction, let go of the button and immediately
press it again. When the desired intensity has been reached, let go
of the 'select' button or the connected control.
keep pressed = dim up
let go and then keep pressed = dim down
Press the programming button for >2s to save the settings and exit
the programming mode.
EN
prog
select
prog
> 2s.