background image

 

 

 

OVERVIEW 

 

 

 

 

INSTALLING THE BULB 

 

Unscrew  the  lamp  cover  of  the  luminaire  and  install  a 

150W J-type lamp. 

 

Re-fit the lamp cover and tighten the screws.       

     

                                                                       

 

 

 

IMPORTANT: THE INSTALLATION OF THIS FITTING MUST BE DONE BY A QUALIFIED ELECTRICIAN. 

 

This fitting must be earthed. 

 

Do not mount the luminaire against inflammable surfaces. 

 

The motion detector will not operate correctly if it is installed: 

( ) Near the outlet of a central heating boiler   

( ) Near air conditioning plant   

( ) Pointing directly at moving vehicles   

( ) Within sight of reflection from moving water   

( ) Where other lamps could shine onto the detector

 

 

The maximum rating of this luminaire is 150 Watts. Check that the total load of the circuit including this 

luminary does not exceed the rating of the circuit cable.                                                                                                                             

NOTE:

 This highly responsive unit may occasionally activate due to rapid environmental changes.    Allow for 

approximately 30 seconds warm-up time before the sensor resumes normal activity.                                                                                                                               

 

 

 

 

 

 

Push-button 

3 motion sensors 

WARNING ! ! ! 

BEFORE ATTEMPTING ANY INSTALLATION OR 

MAINTENANCE, ENSURE THAT THE 

ELECTRICAL SUPPLY IS SWITCHED OFF AND 

THE CIRCUIT FUSES REMOVED OR THE 

CIRCUIT BREAKER IS IN THE “OFF”POSITION. 

 

Содержание nw1010X

Страница 1: ...1 Motion tracking sensor halogen light Installation operating manual NIGHTWATCHER alarm plus Model no nw1010X ...

Страница 2: ...ll instructions carefully even if you feel you are quite familiar with the appliance Any alterations or additions to building wiring must be completed by a licensed electrical mechanic or person authorised by legislation to work on the fixed wiring of any electrical installation To prevent electric shock please ensure that power is disconnected before installing The appliance is not intended for u...

Страница 3: ... at moving vehicles Within sight of reflection from moving water Where other lamps could shine onto the detector The maximum rating of this luminaire is 150 Watts Check that the total load of the circuit including this luminary does not exceed the rating of the circuit cable NOTE This highly responsive unit may occasionally activate due to rapid environmental changes Allow for approximately 30 sec...

Страница 4: ...ATION IF THE TAPE COMES OFF THE LIGHT PLEASE REPLACE IT OR HOLD THE LIGHT HEAD TO AVOID SWIVELING AND DAMAGE THE PRODUCT WIRING INSTRUCTIONS Feed the cable through the back mounting box and bush the cable entry to avoid abrasion to the cable Connect the earth wire to the connector opposite the green yellow cable Connect the brown phase conductor active to the connector opposite the brown cable and...

Страница 5: ...ght only and alarm works on day and night factory setting All day mode light and alarm work on day and night Reset function If the stepper motor of tracking light works abnormally the hidden LED indicator will flash in red and the light will stop turning automatically In All Day Mode the red light will flash on and off for 5 seconds in Night Mode the red light will flash in regular patterns Simply...

Страница 6: ...ch off the unit from the mains power Allow bulb to cool before attempting to remove it Unscrew the lamp cover and take the old lamp out and replace with new one close the lamp cover and tighten the screws WARNING This fitting will become hot when in use Allow bulb to cool before touching Never touch the bulbs with your bare hands Always use a clean cloth when handling the bulbs NOTE THE INTELLIGEN...

Страница 7: ...attery installed correctly Batteries not included Re fit the battery cover to warning device SETTING THE SYSTEM CODE The system code MUST be set before using this alarm unit Please check that the system code set on your motion Sensor floodlight is the same as this alarm unit for example If the code is 41 on your motion sensor floodlight the code must be 41 on the alarm unit This code is also on th...

Страница 8: ... is well secured FUNCTION AND OPERATION The tracking light can also work with RF wireless receiver Warning device is a wireless receiver with alarm function equipped with volume adjustment and low battery indicator As motion sensor detects movement it will send a signal to warning device The alarm will be triggered for 30 seconds and off automatically The control distance between the tracking ligh...

Страница 9: ... abuse If the product ahs been disassembled or tempered with in any way If the product is not drilled mounted and used in accordance with the instructions Note Warranty excludes consumable parts such as tubes globes and batteries YOUR WARRANTY FORM SHOULD BE RETAINED BY YOU AT ALL TIMES SHOULD YOU HAVE ANY QUESTIONS PRIOR TO RETURNING YOUR PRODUCT FOR WARRANTY OR REPAIR PLEASE TELEPHONE OUR CUSTOM...

Отзывы: