background image

Bayco Products, Inc. • 640 South Sanden Blvd. • Wylie, TX 75098 • 1-800-233-2155 • 1-469-326-9400 • www.nightstick.com

INS-XPP-5566-18

11-26-2018

Instruction Manual 

Intrant

®

 XPP-5566

US PATENT 9,713,217 & 10,119,663

Please read these instructions before using your Nightstick XPP-5566 Intrinsically 

Safe Multi-Function Angle Light with Articultaing Head. They include important safety 

information and operating instructions.  

THE XPP-5566 IS APPROVED FOR USE

CLASS I DIV 1 GRPS A-D T3
CLASS II & III DIV1 GRPS E-G T135°C
CLASS I ZONE 0 AEx ia IIC T3 Ga

Ex ia op is I Ma
Ex ia op is IIC T3 Ga
DEMKO 17 ATEX 1927
IECEx UL 17.0082
-20ºC ≤ Tamb ≤ +40ºC
1.5V/Cell Alkaline
3.7V/Cell Li-ion
IP-67
Um: 10V

0359

INTRINSICALLY SAFE

SECURITE INTRINSEQUE

I M1 Ex ia op is I Ma
II 1 G Ex ia op is IIC T3 Ga

E 467756

Bayco Products, Inc.     XPP-5566

Ex ia FLASHLIGHT FOR USE IN HAZARDOUS LOCATIONS

For use with Bayco Li-ion Battery Pack 5568-BATT or 

5566-CARRIER with 3 AA Energizer Type EN91 or E91 

batteries only  

ELECTRICAL SAFETY

640 S. Sanden Blvd., Wylie, TX 75098

Control Drawing: 5568-CERT-DWG1-03

ID 4003544

INMETRO

Segurança

NCC

Ex ia op is I Ma

Ex ia op is IIC T3 Ga (-20ºC ” Tamb ” +40ºC)

18.0110 X

WARNINGS - INTRINSICALLY SAFE

 

y

WARNING: Use only the approved Nightstick 5568-BATT Lithium-ion rechargeable 

battery pack or the approved non-rechargeable batteries listed in special condition of 

use in bullet 4.

 

y

WARNING: To prevent ignition of a hazardous atmosphere, do not open any part 

or attempt to exchange any of the supplied battery packs while in the hazardous 

environment.  This task must ONLY be performed in an area known to be non-

hazardous.

 

y

Warning: To prevent ignition of a hazardous atmosphere, the approved Nightstick 

5568-BATT Lithium-ion rechargeable battery pack must only be charged in an area 

known to be non-hazardous.

 

y

WARNING: When using non-rechargeable batteries in the Nightstick 5566-CARRIER, 

use only 

Energizer EN91

 or 

Energizer E91

 batteries.

 

y

WARNING: To prevent ignition of a hazardous atmosphere, non-rechargeable AA 

batteries must only be changed in an area known to be non-hazardous.

 

y

WARNING: To reduce the risk of explosion, do not mix new non-rechargeable 

batteries with used non-rechargeable batteries, or mix non-rechargeable batteries 

from different manufacturers.

 

y

WARNING: Substitution of components may impair intrinsic safety.

 

y

WARNING: This equipment could be susceptible to electrostatic charge as it 

measured capacitance of 4 pF from external metal parts to earth.

SPECIAL INSTRUCTIONS FOR INTRINSIC SAFETY

 

y

For personal safety, always confirm the rating of any known hazardous or potentially 

hazardous location where the Angle Light is to be used.

 

y

Only devices directly connected to apparatus complying with the IEC 60950 series 

are allowed.

STROBE WARNING

Exposure to strobing lights may cause dizziness, disorientation, and nausea. A very 

small percentage of people suffer from photosensitive epilepsy and may experience 

seizures or blackouts triggered by strobing lights. For more information from the 
EPILEPSY FOUNDATION about photosensitivity and seizures, please visit 

www.

epilepsy.com

. Anyone who has had symptoms linked to this condition should consult a 

doctor before using this product.

POWERING THE XPP-5566

The XPP-5566 Intrinsically Safe Light is powered by the Nightstick 5566-CARRIER 

Non-Rechargeable Battery Carrier and 3 - AA 

Energizer EN91

 or 

Energizer E91

 

Batteries. The 5566 is sold only with a primary battery pack. It can be made rechargeable 

if a secondary battery pack kit is purchased.

WARNING: Do not use any other type of non-rechargeable battery with this light.
WARNING: Do not use rechargeable AA batteries with this light.

5566-CARRIER NON-RECHARGEABLE BATTERY CARRIER

WARNING: The Nightstick 5566-CARRIER Non-Rechargeable Battery Carrier is a 

proprietary shape and design and will only fit in the XPP-5562, XPR-5564, XPP-

5566 and XPR-5568 Angle Lights.  Do not attempt to use this battery pack in any 

other light.  Do not attempt to use any other battery pack in this light.

 

y

The Nightstick 5566-CARRIER Non-Rechargeable Battery Carrier is designed to 

fit 3 AA batteries.  In order to maintain the XPP-5566’s Intrinsically Safe Permissible 

rating, the only AA batteries certified for use with this light are the 

Energizer EN91

 or 

Energizer E91

.

 

y

Do not attempt to use any other brand or model of AA batteries with this light.

 

y

Do not attempt to use any type of rechargeable AA batteries with this light.

Removing the Non-Rechargeable Battery Carrier
WARNING: To prevent ignition of a hazardous atmosphere, do not open the battery 

compartment in the hazardous environment.  This task must ONLY be done in an 

area known to be non-hazardous.

 

y

To access the 5566-CARRIER Non-Rechargeable Battery Carrier, unscrew the 

screw located on the Battery Compartment Door on the base of the light.

NOTE:  The Battery Compartment Door Screw utilizes a design that prevents the 

screw from falling out of the door.  Do not attempt to remove the screw.

 

y

Open the Battery Compartment Door with enough clearance to allow the 

5566-CARRIER Non-Rechargeable Battery Carrier to slide out.

Installing or replacing the batteries

 

y

Begin by positioning the 5566-CARRIER Non-Rechargeable Battery Carrier with the 

arrow pointing to the left.

 

y

Using 3 – AA 

Energizer EN91

 or 

Energizer E91

 (make sure that all 3 batteries are of 

one or the other model…do not use a combination of the two), install the batteries per 

the diagram located on the base of the battery carrier.

 

y

Take care not to bend any of the battery contact springs, and to make sure that all 3 

batteries are properly seated before installing into the angle light. 

NOTE: The battery carrier cover will only fit one way.  It is not possible to install it 

in a reversed position.

The Nightstick 5566-CARRIER Non-Rechargeable Battery Carrier is ready to 

install into the Angle Light.  Installation of the 5566-CARRIER Non-Rechargeable 

Battery Carrier into the Angle Light is the same as installing the 5568-BATT Lithium-ion 

Battery Pack.  Please see the instructions listed above in the 

5568-BATT LITHIUM-ION 

RECHARGEABLE BATTERY PACK

 section.

Installing the Non-Rechargeable Battery Carrier

 

y

With the Battery Compartment Door opened enough to provide clearance, insert 

the 5566-CARRIER Non-Rechargeable Battery Carrier with the end having the metal 

contacts on it being inserted first.

 

y

With the battery carrier fully inserted into the handle of the light, close the Battery 

Compartment Door and secure it in place with the Battery Compartment Door Screw.

WARNING: Do not over-tighten the Battery Compartment Door Screw.

OPERATION

THE XPP-5566 HAS 8 SEPARATE LIGHTING MODES:
Flashlight Modes

To activate the Flashlight, press and release the Flashlight Switch. The default mode 

will be High-brightness. To select the brightness level for the Flashlight, press and hold 

the Flashlight Switch. The flashlight will cycle from high to medium to low at a rate of 

approximately one mode per second. The light will continue to cycle through the various 

modes as long as the switch is held down. When the desired brightness level is reached, 

release the Flashlight Switch and the light will remain in that brightness mode. To turn the 

Flashlight off, press and release the Flashlight Switch one more time.

Strobe

To activate the Strobe, double click the Flashlight Switch. To turn the Strobe off, 

press and release the Flashlight Switch one more time.

Floodlight Modes

To activate the Floodlight, press and release the Floodlight Switch. The default mode 

will be High-brightness. To select the brightness level for the Floodlight, press and hold 

the Floodlight Switch. The floodlight will cycle from high to medium to survival at a rate of 

approximately one mode per second. The light will continue to cycle through the various 

modes as long as the switch is held down. When the desired brightness level is reached, 

release the Floodlight Switch and the light will remain in that brightness mode. To turn 

the Floodlight off, press and release the Floodlight Switch one more time.

Dual-Light Mode

Dual-Light mode allows the user to turn on both the Flashlight and the Floodlight 

at the same time. Dual-Light mode can be activated by simply pressing the Flashlight 

Switch and then the Floodlight Switch at the same time. If the Angle Light already has 

the Flashlight or the Floodlight on (regardless of what brightness mode that light is in), 

pressing the switch for the light that is NOT on, will activate Dual-Light mode. The user 

can leave Dual-Light mode and go back to either Flashlight or Floodlight mode simply by 

pressing the switch for the mode that they wish to turn off. To turn both lights off, simply 

press each of the switches independently.

Содержание Intrant XPP-5566GX

Страница 1: ... the Energizer EN91 or Energizer E91 y y Do not attempt to use any other brand or model of AA batteries with this light y y Do not attempt to use any type of rechargeable AA batteries with this light Removing the Non Rechargeable Battery Carrier WARNING To prevent ignition of a hazardous atmosphere do not open the battery compartment in the hazardous environment This task must ONLY be done in an a...

Страница 2: ...SSEMENT Ne pas utiliser d autres types de piles non rechargeables avec cette lampe AVERTISSEMENT Ne pas utiliser de piles AA rechargeables avec cette lampe LE PORTE BATTERIE NON RECHARGEABLE 5566 CARRIER AVERTISSEMENT Le porte batterie non rechargeable Nightstick 5566 CARRIER est spécialement conçu avec une forme et un concept exclusifs et conviendra uniquement aux lampes à angle XPP 5562 XPR 5564...

Страница 3: ...recargables de diferentes fabricantes y y ADVERTENCIA La sustitución de componentes puede perjudicar la seguridad intrínseca y y ADVERTENCIA Este equipo podría ser susceptible a la carga electrostática ya que midió la capacitancia de 4 pF capacidad básica de electrodos de las partes metálicas externas a la tierra INSTRUCCIONES ESPECIALES PARA LA SEGURIDAD INTRÍNSECA y y Para su seguridad personal ...

Страница 4: ...s baterias fornecidas enquanto estiver em um ambiente perigoso Esta tarefa só deve ser realizada em uma área conhecida como NÃO PERIGOSA y y Aviso Para evitar a ignição de uma atmosfera perigosa o pacote aprovado de baterias recarregável de íon de lítio Nightstick 5568 BATT só deve ser carregado em uma área que não seja perigosa y y Aviso Quando utilizar pilhas não recarregáveis no Nightstick 5566...

Страница 5: ...e Nightstick XPP 5566 Taschenlampe verwenden Die Anleitung enth lt wichtige Sicherheitshinweise und Bedienungsanweisungen DIE XPP 5566 STIRNLAMPE IST ZUM GEBRAUCH ZUGELASSEN CLASS I DIV 1 GRPS A D T3 CLASS II III DIV1 GRPS E G T135 C CLASS I ZONE 0 AEx ia IIC T3 Ga Ex ia op is I Ma Ex ia op is IIC T3 Ga DEMKO 17 ATEX 1927 IECEx UL 17 0082 20ºC Tamb 40ºC 1 5V Cell Alkaline 3 7V Cell Li ion IP 67 Um...

Страница 6: ...hraube an der Batteriefachtür nicht zu fest an INBETRIEBSETZUNG y y Die XPP 5566 hat acht separate Beleuchtungsarten y y Hohes Helligkeits Blinklicht y y Mittleres Helligkeits Blinklicht y y Überlebensmodus Blinklicht y y Stroboskop Blinklicht y y Hohes Helligkeits Flutlicht y y Mittleres Helligkeits Flutlicht y y Überlebensmodus Flutlicht y y Duales Licht sowohl Blinklicht als auch Flutlicht sind...

Страница 7: ...5568 GX RX Type Flashlight ATEX Directive 2014 34 EU The following harmonised standards and technical specifications have been applied Evaluated to the following safety standards by Underwriters Laboratories U L EN 60079 0 2012 A11 2013 EN 60079 11 2012 ia EN 50303 2000 These Products are fully compliant and do not contain the restricted substances above levels noted in EU RoHS Certificate No DEMK...

Отзывы: