TM Eco Series
Operating & Safety Instructions
USA – 07/11
Issue 01
18
HYDRAULIC OUTRIGGERS (TM34H) MODELS
9)
Ensure that the key switch at the ground control station is turned to the “ON” position (i.e.
clockwise).
10)
At the outrigger control station press down and hold the power lever on the right hand side. This
activates the power and diverts hydraulic flow to the legs for setting up. Then select the
appropriate control lever to begin set up.
Note: No power will be available if the booms are not
stowed onto the boom rest.
11)
Using the four outrigger control levers, lower each outrigger onto a firm, surface and level the
machine base ensuring each outrigger foot is taking equal weight with the wheels clear of the
ground.
Note: Deploy the front two outriggers first to minimise the risk of damaging
the jockey wheel.
12)
Check that the base is level using the spirit level adjacent to outrigger control station.
13)
The booms can now be operated from the ground control station by pressing and holding the
green power button.
Note: If the klaxon alarm sounds, check that each outrigger is lowered and
each footpad is taking equal weight.
14)
To operate the booms from the basket, remove the key from the ground control station (turn key
anti-clockwise) and put the key in the basket control station and switch to “ON” (clockwise).
Note: If the klaxon alarm sounds, check that each outrigger is lowered and each footpad is
taking equal weight
.
ALL MODELS
15)
Always lower booms fully before adjusting, raising, retracting or moving the outriggers in any
way.
16)
Never alter, modify or block any of the safety circuits on the Niftylift.
THIS MACHINE IS NOT ELECTRICALLY INSULATED. DO NOT WORK WITHIN
10FT OF OVERHEAD CABLES EXCEEDING 415 VOLTS
Содержание TM34M ECO Series
Страница 2: ......