SETTING UP PROCEDURES
FAILURE TO DEPLOY THE OUTRIGGERS CORRECTLY COULD RESULT
IN DEATH OR SERIOUS INJURY.
ALL MODELS
1)
Read and fully comply with all safety precautions and operating instructions in the Operating and
Safety manual and the warning decals on the machine.
2)
Position Niftylift on firm ground, bearing in mind range of boom movement so that any overhead
obstructions or possible hazards such as, but not limited to, power cables, telephone lines,
drains, manhole covers, etc. can be safely avoided
3)
If the load bearing capacity of the ground is in any doubt the machine must
NOT
be used.
4)
Levelling the machine using the hydraulic outriggers can accommodate a slope of up to 12
degrees, if necessary using suitable load bearing pads to support the downhill jacks. Do not
elevate the platform unless the base can be corrected to within three degrees of level.
5)
Chock wheels and cordon off area using appropriate cones, barriers and flags.
6)
Check all red emergency stops are not engaged i.e. fully out.
7)
Ensure Base/Basket selector is turned up to basket position.
8)
From the basket control station depress the footswitch to give hydraulic power to the outriggers.
Note: No power will be available if the booms are not stowed onto the boom rest.
9)
Using the four outrigger control switches, lower each outrigger onto a firm, level surface and
level machine base ensuring each outrigger foot is taking equal weight with the wheels clear off
the ground. Each switch has a light that will turn off once the outrigger foot has been correctly
deployed.
10)
Check machine is level using spirit level on the base, visible from the basket.
11)
The booms can now be operated from the basket control station by depressing the footswitch.
Note: If no power is available check each outrigger is lowered and each footpad is taking equal
weight.
12)
Always lower booms fully before adjusting, raising, retracting or moving the outriggers in any
way.
13)
Never alter, modify or block any of the safety circuits on the Niftylift.
THIS MACHINE IS NOT ELECTRICALLY INSULATED. DO NOT WORK WITHIN
10FT OF OVERHEAD CABLES EXCEEDING 415 VOLTS