Mechanical installation
4.1
General installation
Figure 4-1
Installation on Unidrive M200 to M400 and Commander C200 / C300
(frames 2 to 4)
•
With the option module tilted slightly backwards, align and locate the two holes in
the rear of the option module onto the two tabs (1) on the drive.
•
Place the option module onto the drive as shown in (2) until the module clicks into
place. The terminal cover on the drive holds the option module in place, so this must
be put back on.
Before installing or removing a System Integration module, ensure the AC supply
(and any DC supply) has been disconnected for at least 10 minutes.
WARNING
Option modules can only be installed on drives that have the option module slot
functionality.
NOTE
NOTE