9.2 During operation monitor the following: 

 
- Operating temperature 

When using mineral gear oils (CLP) the operating temperature should not exceed 90°C or only exceed this limit 
for a short period of time. When using synthetic gear oils (CLP), an operating temperature of 110°C for a short 
period of time is permissible if all sealing rings are made of FKM (fluorocarbon rubber, 

“Viton”), whereby it must 

be ensured that the shaft seals on the drive shafts are already FKM as standard. 
See also Section 11.3 Oil Service Life  

 

- Changing gearbox noises, vibrations. 
 
- Oil leakage 

on the housing and on the shaft seal rings. 

 

- Oil level 

– for oil level checking, the gearbox must be shut down.  

Check oil levels only with the gearbox in a cooled down condition: 

 

If an oil inspection glass is available, the oil level shown must be at the centre of the oil inspection 
glass. 
 

 

Without an oil inspection glass, the check is carried out on the screw plug, if present, of a vertical 
housing surface. The oil level must be in contact with the thread in the housing. 

 

       

 

   

 

Attention 

Insufficient lubrication caused by an excessively low oil level may cause damage 
to the geared parts and the bearings! 
 
Carry out a regular oil level check 

 

  

 

Warning

Serious burns possible on hot surfaces (>55°C)  
 
Wear suitable gloves and additional protective clothing 

 
 
 

9.3 Irregularities 

 

In the event of any changes in relation to standard operation, e.g. increased temperatures, noises, vibrations, 
the gearbox must be shut down in any case of doubt so that the cause of such changes can be determined. 
See Section 10: 

“Faults, causes, remedy”. 

If necessary, contact our Service Department for consultations. 

 
 
 
 
 
 
 
 

10. Faults, Causes and Remedies 

 

10.1 General Fault Indications 

 Se

ctions 5 “Safety Information” and 11 “Inspection and Maintenance” must be observed! 

 
Faults occurring during the warranty period which necessitate a repair of the gearbox must only be corrected by 
Service Department employees of Nidec Graessner. 
 
The Nidec Graessner Service Department should also be contacted after the warranty period has expired if 
faults occur whose cause cannot be clearly identified. 

 
 

Содержание EG115

Страница 1: ...gahe BA EvoGear status as of July 13 2021 Page 1 of 22 Servo Angular Gears EVOGEAR EvoGear L LSV EG55 to EG115 EvoGear PLS EG55 to EG115 EvoGear PLT EG55 to EG115 Installation and Operating Instructio...

Страница 2: ...netary Gear Stage 4 6 Type Plate and Designations 6 6 6 8 8 9 9 5 Safety Information 5 1 Fundamental Obligations 5 2 Qualified Personnel 5 3 Environmental Protection 10 10 10 10 6 Transport Storage an...

Страница 3: ...Inspection and Maintenance 11 1 General Information 11 2 Maintenance Periods 11 3 Oil Service Life 11 4 Oil Change 11 5 Checking the Gearbox Condition 19 19 19 19 20 20 12 Replacement Parts Stocking...

Страница 4: ...m to the current status of the description as contained in these operating instructions We reserve the right to make technical changes to components while maintaining the performance characteristics a...

Страница 5: ...are intended for incorporation into machines and are to be used exclusively for the deflection distribution and multiplication of torques They comply with the Machinery Directives EN ISO 12100 and EM...

Страница 6: ...nitrile rubber Perbunan and FKM fluorocarbon rubber Viton flange seals by laminated sealing washers The ratios are mathematically accurate from 3 00 1 to 100 1 in the standard version Gearbox in a ful...

Страница 7: ...ull shaft and planetary gear stage with motor lantern and metal bellow type coupling on the drive side Shown PLS range for mounting on side 1 EvoGear PLT Output with planetary gear stage and robot fla...

Страница 8: ...28 35 40 50 70 118 280 590 1300 i 100 88 220 440 930 For the max acceleration torques and the emergency stop torques please refer to the performance tables in the catalogue which can be downloaded at...

Страница 9: ...h Ex Protection Protection class 20 000 S5 load spectrum as design basis synthetic gear oil POA base ISO VG 150 any 10 C to 90 C Primer RAL 9005 black silver Explosion proof gearboxes available on req...

Страница 10: ...owledge of these operating instructions All specialists must wear protective clothing that is appropriate to their work 5 3 Environmental Protection All existing packaging material must be disposed of...

Страница 11: ...with 6 2 Storage Conditions EvoGear gearboxes may only be put into storage in a closed condition in a dry dust free and low vibration environment avoidance of standstill damage without sunlight at tem...

Страница 12: ...e housing must be avoided tension free assembly with combined flange or push on attachment exact alignment of the gearbox for direct coupling comply with the manufacturer s instructions 7 3 Attachment...

Страница 13: ...lack M4 M5 M6 M8 M10 5 Nm 8 5 Nm 14 Nm 35 Nm 69 Nm b Mounting the Motor Preferred installation in the vertical position Always position the motor shaft with the gear shaft such that it is in alignment...

Страница 14: ...cal Insert the motor into the gearbox from below The motor must be in tension free contact with the gearbox flange then screw in screws using screw locking paste and tighten crosswise to the prescribe...

Страница 15: ...see catalogue Drive and output elements must be covered by contact protection 7 5 Final Work Before fitting protective covers check the correct oil level in the gearbox if possible Check for even runn...

Страница 16: ...tional speed is reached running in time at idle approx 90 min During start up and run up pay attention to running noise and temperature development in particular at the bearing points In the case of u...

Страница 17: ...plug if present of a vertical housing surface The oil level must be in contact with the thread in the housing Attention Insufficient lubrication caused by an excessively low oil level may cause damage...

Страница 18: ...at the ventilation filter Oil foams Oil level in the gearbox too high Incorrect design of the ventilation See fault Oil foams in gearbox Decrease oil level in gearbox to the specified level Prevent an...

Страница 19: ...Therefore it must be ensured that these maintenance periods are observed Measures Maintenance Periods Remarks Check running noise for any changes daily Check the gearbox for leakage daily Check oil l...

Страница 20: ...lutinate and then precipitate into the gearbox 11 5 Checking Gearbox Condition This check may only be carried out by qualified operating personnel or by the Nidec Graessner Service Department Here it...

Страница 21: ...use of Nidec Graessner gearboxes 1 2 2 4 5 Operation 9 16 Operating temperature 9 2 17 Aeration and ventilation filter 8 16 Downloads Notes 1 4 4 6 5 9 Disposal of the gearbox after use 5 3 10 Replace...

Страница 22: ...nations 4 2 6 Type plate 4 6 9 Conversions and changes modification of the product Environmental protection 3 5 3 5 10 Irregularities 9 3 17 Copyright Commissioning after long term storage 1 4 6 4 4 1...

Отзывы: