22
Part # M017879450000 REV. July 1, 2011
ECOTECH EZ
TM
Variable Speed Motor/Control
reset to factory Defaults
Resetting the factory defaults will return the programmable
settings to the factory defaults. Activating the reset to
factory default option is done by pressing the Left arrow
button, the Exit button, and the Run/Stop button. When
this button combination is pressed for more than two
seconds the reset to factory defaults mode will activate.
The following will be reset to the factory default settings:
the program Schedule:
Mon – Fri Flow 1: 7:30AM Time On and 4:00PM Time Off
running at 50% Flow
Mon – Fri Flow 2: 4:00PM Time On and 6:00PM Time Off
running at 70% Flow
Sat –Sun Flow 1: 7:30AM Time On and 4:00PM Time Off
running at 50% Flow
Sat – Sun Flow 2: 4:00PM Time On and 6:00PM Time Off
running at 70% Flow
the custom flow 1 Setting:
80% Flow for a duration of 120 minutes
Backup power Supply
In the event the power would go out and not supply your
ECOTECH EZ
TM
motor/control, the user interface will keep
the current day of the week settings and the time of day
settings for 12-16 hours without power to the motor. Your
Program Schedule and your Custom Flow settings will
remain intact in the event the power is out longer than
12-16 hours. Should the power outage extend longer than
the backup power supply, reset your clock and day of the
week to resume operations.
NOTICE
!
These instructions can be found on page
13 of this guide.
Locking the Keypad
To prevent inadvertent or unauthorized changing of the
program parameters, the keypad can be locked. To lock
the keypad, use the following procedure:
1.
Press the ENTER and the Exit buttons simultaneously
and hold for 2 seconds. After 2 seconds the
“Press ENTER to Confirm” icon in the display
will start blinking.
2.
Press Enter.
The keypad is now locked, and the letters “LOC”
will be shown in the display for 5 seconds.
After 5 seconds, the letters “LOC” will go off, and
the display will revert back to showing the Time,
Day of Week, % Flow rate, operating mode the unit
was running (i.e. Mon-Fri Flow 1, Custom Flow, or
Vacuum). (If keypad lockout is activated while in
Custom Flow or Vacuum mode, those modes will
continue to operate and time out per the programmed
times. When those operating modes are complete,
the unit will either revert back to the appropriate Mon-
Fri or Sat-Sun programmed modes or the motor will
stop depending on which mode the unit was in prior
to entering the Custom Flow or Vacuum mode)
Pressing of any button on the keypad (other than the
RUN/STOP button), while the keypad is locked will
cause the display to completely blank except for the
letters “LOC” which will be displayed for 5 seconds
after the button is pressed. After 5 seconds, the
display will revert back to what was being displayed
prior to the button press.
Pressing of the Run/Stop button while the keypad
is locked, will either stop the motor if it was running
and turn off the RUN/STOP LED, or start the motor in
program mode if it was stopped and turn on the RUN/
STOP LED.
Note: If a power outage occurs while the keypad
is locked, when power is restored the keypad will
remain locked.
to exit the keypad lockout mode:
1.
Press the ENTER and the Exit buttons simultaneously
and hold for 2 seconds. For the first 2 seconds, the
display will show the letters “LOC”. After 2 seconds,
“LOC” will go out and the “Press ENTER to Confirm”
icon will start blinking.
315612_MNJ26_VAR SPD_nonSRVS.indd 22