19
Press the ENT key to return
to the LED display test.
Display
Description
Countermeasure
1
Mode 1, 4: Displayed when the display is overflowed (the
display value exceeds the available number of display digits).
Mode 2, 3: Displayed when the auto zero function is executed,
or the input is less than the minimum revolution speed.
When the input signal becomes within the measurement range
(available number of display digits), the measurement value is
displayed.
2
Displayed when the input pulse width is 10ms or less in
mode 3 (time wide meter mode).
Change the input pulse width to within the measurement
range.
3
Displayed when the value is outside the teaching function
range (when the input revolution speed is 99,999 or more).
*For details, refer to page 7 (detailed teaching function).
Decrease the input revolution speed and execute the teaching
function.
4
Displayed when an internal memory error occurs.
Press the ENT (MODE) key to release the error.
Note that the setting values of modes, parameters, and
functions are initialized.
5
Displayed when the setting value F01 is less than F02, or
F03 is less than F04 in the function setting mode.
After the error code is displayed for 2 seconds, the display
returns to the previous status before EE-4 is displayed.
Change the settings.
-. -. -. -. -. -.
E E - 1
E E - 2
E E - 3
E E - 4
BTM
<<
●
●
>>
<<
MAX MIN TEA PEAK BTM
Normal display
LED display test
Key test
Version display
Mode display
Test mode
Press and hold the SHIFT + MODE keys for 5 seconds or more.
Press the key to change the mode number to “99”.
Press the SET key to display the LED display test.
Press the ENT key to display
the software version.
Press the MEN key to display
all LED digits.
Press the MEN key to display
the key test display.
Press the SET key to return to the normal display.
Press the MEN key to display “1” in the 2nd digit
place from the left, and release it to display “0”.
Press the key to display “1” in the 3rd digit
place from the left, and release it to display “0”.
Press the key to display “1” in the 4th digit
place from the left, and release it to display “0”.
Displays the measurement value.
Press the ENT key to return to the LED display test.
Press the MEN key to return
to the LED display test.
Displays the measurement value.
Displays the current set mode number.
The LED on the main display lights up.
”000000 > 999999” is repeatedly displayed.
Also, the decimal point and display lamp
light up sequentially.
0
0 0 0 0 0 0
0 0 0
1 0 0
0 1 0
0 0 1
0
8 8 8 8 8 8
8. 8:. 8. 8:. 8. 8.
9 9 9 9 9 9
v
1. 0 0
- 0 1 -
- 9 9 -
20.
Test Mode (Function to Check if the Unit is Operating Normally)
21.
Error Display
When an error occurs during operation, the following error codes are displayed. Take appropriate countermeasures
based on the displayed code.
s
s
s