16
Continued on next page
● Setting example : 1000
● Setting example : 500
● Setting example : 1200
● Setting example : 300
● Setting example : 20
● Setting example : 3
● Setting example : 100
Normal display
Function 1 setting
Function 2 setting
Function 3 setting
Function 4 setting
Function 5 setting
Function 6 setting
Function 7 setting
• Function setting item <in mode 1 (digital tachometer mode)>
No.
Setting item
Setting range
Default setting
Function description
Display
Description
F1 High set point 1 value*
000000 - 999999
000000
0
Sets the high set point 1 value. The decimal point is not displayed.
F2
Low set point 1 value*
000000 - 999999
000000
0
Sets the low set point 1 value. The decimal point is not displayed.
F3 High set point 2 value*
000000 - 999999
000000
0
Sets the high set point 2 value. The decimal point is not displayed.
F4 Low set point 2 value*
000000 - 999999
000000
0
Sets the low set point 2 value. The decimal point is not displayed.
F5
Hysteresis of the high
and low set point 1 values
0 - 99
_ _ _ _ 00
0
Sets the hysteresis of the high and low set point 1 values. Used when the
revolution variation is large.
(For details, refer to "Comparator Function" on page 17.)
F6
Judgment output timer
at startup
0 - 99 sec.
_ _ _ _ 00
0 sec.
Sets the time when the comparator judgment is output at startup
F7 Minimum revolution speed
000000 - 999999
000000
0
Sets the revolution speed to be displayed as zero
F8
Frequency of the moving
average
0(disabled)/1(3 times)/2(10 times)
_ 0 _
0(disabled)
Used when variation of the revolution speed is large and a stable display
cannot be attained
F9 Pre-arithmetic function
0(disabled)/1(enabled)
_ 0 _
0(disabled) Promptly performs the deceleration display when the signal is lost
*For the settings of the high set point 1 and 2 values, as well as the low set point 1 and 2 values, refer to “Comparator Function” on page 17.
To the function settings
The main display shows “0”.
0
0 1 - F 0 1
0 1 - F 0 1
0 0 1 0 0 0
0 0 0 5 0 0
0 0 1 2 0 0
0 0 0 3 0 0
0 0 0 1 0 0
- - - -
2 0
- - - -
0 3
0 0 0 0 0 0
0 0 0 0 0 0
0 0 0 0 0 0
0 0 0 0 0 0
- - - -
0 0
- - - -
0 0
P r e s s t h e S H I F T + F U N C
keys for 5 seconds or more to
switch to the parameter set-
ting mode.
Press the ENT key and start
setting functions.
Every time you press the key,
the display switches to the next
parameter.
17.
Setting Method of Functions (Excluding in the Test Mode, Common in Each Mode)
The setting method of the functions is common in each mode excluding the test mode.
For the lists of functions in each mode, refer to page 21.
• Setting method <in mode 1 (digital tachometer mode)>
For the setting methods in other modes than mode 1 (digital tachometer mode), also refer to the description below.
Use the key to move to another digit
Use the key to change the numerical value
to “1000”.
Use the ENT key to finish setting.
Use the key to move to another digit
Use the key to change the numerical value
to “500”.
Use the ENT key to finish setting.
Use the key to move to another digit
Use the key to change the numerical value
to “1200”.
Use the ENT key to finish setting.
Use the key to move to another digit
Use the key to change the numerical value
to “300”.
Use the ENT key to finish setting.
Use the key to move to another digit
Use the key to change the numerical value
to “20”.
Use the ENT key to finish setting.
Use the key to move to another digit
Use the key to change the numerical value
to “03”.
Use the ENT key to finish setting.
Use the key to move to another digit
Use the key to change the numerical value
to “100”.
Use the ENT key to finish setting.
s
s
s
s
s
s
s
s
s
s
s
s
s
s
s
www.calcert.com
1.888.610.7664
0
5
10
15
20
25
30