Nidac Presco 3 Series Скачать руководство пользователя страница 6

3

 

TERMINAL DESCRIPTIONS 

GND 

Negative input (or ground) from the power supply. 

AC-DC 

A.C. 16 - 24 Volt or D.C. 12 - 24 Volt positive input 
from the power supply. 

DTA 

Data line to encoder (white wire on keypads). 

LED

 

Output to drive a LED to indicate door unlocked. 

ELC 

(Electric Latch Control) 5 Amp relay output.  The 
ELC relay is used to control the door 
locking/release mechanism.  The relay can be 
programmed as either Normally Open for 

fail 

secure

 applications (power applied to 

open

 door) 

or Normally Closed for 

fail safe

 applications 

(power applied to 

lock

 door). 

DOOR 

This input requires a normally closed switch 
connected to ground, typically a reed switch 
attached to the door. The DOOR input is used by 
the PAC1 to monitor when the door is physically 
open (not unlocked).  In order to use this input it 
must first be enabled (via memory 84, refer to 
page 15) and a normally closed (when the door is 
closed) door switch (or monitored lock contacts) 
must be connected between DOOR and GND.  
The DOOR input is used to detect when the door 
has been opened for use by the door forced open, 
Door Open Too Long and automatic relock 
functions. 

DOTL 

(Door Open Too Long) 1 Amp Normally Open 
relay output, operates when a DOTL or Door 
Forced Open alarm condition occurs.

 

Содержание Presco 3 Series

Страница 1: ...PAC1 Single Door Access Controller Series 3 INSTALLATION MANUAL...

Страница 2: ...Relock Function 5 Door Open Too Long 5 Door Forced Open 5 One Minute Lockout 6 High Security Mode 6 Installation 7 VR43 and VR62 Keypad Wiring 7 PRE Keypad Wiring 8 PSE Keypad Wiring 8 PRO2410 Proxim...

Страница 3: ...Time Memory 83 15 Door Input Enable Memory 84 15 Door Open Too Long Timer Memory 85 16 Door Forced Open Detection Memory 86 16 One Minute Lockout Memory 87 16 High Security Mode Memory 88 17 High Sec...

Страница 4: ...to restricted areas FEATURES Split system for maximum security Encoder Decoder Door Forced Open detection Door Open Too Long DOTL function EGRESS function Automatic door relock function Easy on site...

Страница 5: ...2 compatible mode for use with existing PACDL installations 6 Two Codes Mode is now called High Security Mode SPECIFICATIONS Voltage absolute min max 1 11 30 Volts D C 14 28 Volts A C Current 120 mA...

Страница 6: ...tions power applied to lock door DOOR This input requires a normally closed switch connected to ground typically a reed switch attached to the door The DOOR input is used by the PAC1 to monitor when t...

Страница 7: ...her selected features of the PAC1 DOTL Door Forced Open Automatic Relock will also become active at this time Therefore the EGRESS input can be used to hold the door open indefinitely with the use of...

Страница 8: ...efer to page 16 If the door has not closed again by the time this counter expires then the DOTL output will activate contacts will close and will remain active until the door is closed Note that if a...

Страница 9: ...the ELC relay Any Two User Codes Any two of the programmed user codes must be used together to operate the ELC relay Code 000 or 001 and any other user code The user code stored in memory 000 or 001...

Страница 10: ...ensure that the decoder and encoder components are separated and that the decoder is inaccessible to persons outside the restricted area The decoder should be installed indoors and in a dry secure pla...

Страница 11: ...8 PRE KEYPAD WIRING PSE KEYPAD WIRING...

Страница 12: ...are not connected when the PRO2410 is used with a PAC1 decoder Use a 100mA inline fuse to protect the power supply from short circuiting if the PRO2410 wires are tampered with This is particularly im...

Страница 13: ...10 D C LOCK A C LOCK Use 1N4004 diode only when using a Door Strike not a Magnetic Lock or Drop Bolt VOLTAGE FREE CONTACT OUTPUT EGRESS SWITCH INPUT DOOR SWITCH INPUT...

Страница 14: ...program mode The PAC1 will remain in program mode for a period of 5 minutes after the button has been pressed Each time the keypad is used to successfully enter information the 5 minute timeout perio...

Страница 15: ...e key instead of E at the end of the sequence all other steps remain the same CLEAR ALL USER CODES All the user codes memories 000 to 399 can be cleared by the use of the following sequence 8 7 6 5 E...

Страница 16: ...e 15 6 Set Door Open Too Long time Currently 60 seconds Memory 85 page 16 7 Enable Disable DOOR FORCED OPEN DETECTION Currently enabled Memory 86 page 16 8 Enable Disable AUTOMATIC RELOCK Currently en...

Страница 17: ...open or normally closed EGRESS switch setting may be selected To set the EGRESS switch input to N O level triggered 8 1 0 E To set the EGRESS switch input to N C level triggered 8 1 1 E To set the EGR...

Страница 18: ...Memory 83 Factory Default 10 seconds The electronic latch control ELC relay can be set to operate for 1 second to 255 seconds in 1 second increments To change the ELC operate time 8 3 the time in sec...

Страница 19: ...ry Default Enabled Disabling the Door Forced Open function prevents the DOTL output from activating contacts closing when the door is opened without a valid code or EGRESS switch having been used To d...

Страница 20: ...wo User Codes mode 8 8 1 E To select Code 000 or 001 and any other user code mode 8 8 2 E To select Sequential Memory User Codes mode 8 8 3 E IMPORTANT NOTE When the PAC1 is set up to use any of the h...

Страница 21: ...ry codes from turning off toggle 9 1 0 E To Enable momentary codes to turn off toggle 9 1 1 E Series 2 Compatibility Memory 99 Factory Default Disabled Enabling this memory forces the PAC1 Series 3 to...

Страница 22: ...nds Enable Disable DOOR input default disabled 8 4 x E x 0 for disabled x 1 for enabled Set DOTL timer default 60 seconds 8 5 xxxx E xxxx 0 to 9999 seconds Enable Disable Door Forced detection default...

Страница 23: ...ntal or malicious damage under the 36 month warranty offered from the date of purchase As NIDAC Security Pty Ltd or its agents do not perform the final installation inspection or training in the use o...

Страница 24: ...PSE 4x3 Semi Flush Mount vandal and weather resistant keypad for Presco decoders PRO2410 Proximity card reader for PAC1 PAC2 or Wiegand input controller PIM Interface Module for Dallas iButton Clock...

Отзывы: