16
Door Open Too Long Timer
Memory 85
(Factory Default: 60 seconds)
The time allowed for the door to be open before a DOTL
alarm is generated can be set from 1 to 9999 seconds. A
time of zero seconds will disable this function.
To change the DOTL time…
*
8
5
“the time in seconds”
E
Note that time of 0 seconds will disable the DOTL function.
Door Forced Open Detection
Memory 86
(Factory Default: Enabled)
Disabling the Door Forced Open function prevents the
DOTL output from activating (contacts closing) when the
door is opened without a valid code or EGRESS switch
having been used.
To disable Door Forced Open Detection…
*
8
6
0
E
To enable Door Forced Open Detection…
*
8
6
1
E
One Minute Lockout
Memory 87
(Factory Default: Disabled)
Enabling the 1 minute lockout function means that the
system will not accept any codes for 1 minute after 5
successive invalid codes have been entered.
To disable the one minute lockout…
*
8
7
0
E
To enable the one minute lockout…
*
8
7
1
E