19
INSTALLATION PROGRAMMING SUMMARY
Enable/Disable Automatic Relock.
(default = enabled)
*
8
0
x
E
. x =
0
for disabled, x =
1
for enabled.
Select EGRESS switch type. (default
=
N.O.)
*
8
1
x
E
. x =
0
for N.O. level, x =
1
for N.C. level,
x =
2
for N.O. edge, x =
3
for N.C. edge.
Select ELC relay type. (default
=
N.O.)
*
8
2
x
E
. x =
0
for N.O. (fail secure),
x =
1
for N.C. (fail safe).
Set ELC operating time.
(default = 10 seconds)
*
8
3
xxx
E
. xxx = 1 to 255 (seconds).
Enable/Disable DOOR input. (default
=
disabled)
*
8
4
x
E
. x =
0
for disabled, x =
1
for enabled.
Set DOTL timer.
(default = 60 seconds)
*
8
5
xxxx
E
. xxxx = 0 to 9999 (seconds).
Enable/Disable Door Forced detection. (default = enabled)
*
8
6
x
E
. x =
0
for disabled, x =
1
for enabled.
Enable/Disable 1 minute lockout. (default
=
disabled)
*
8
7
x
E
. x =
0
for disabled, x =
1
for enabled.
Select High Security Mode.
(default = Normal Mode)
*
8
8
x
E
. x =
0
for Normal Mode,
x =
1
for Any Two User Codes,
x =
2
for Code 000 or 001 and any other,
x =
3
for Sequentially Stored User Codes.
Set High Security Mode timing.
(default = 60 seconds)
*
8
9
xxx
E
. xxx = 1 to 255 (seconds).