background image

   www.hysecurity.com       

9

2.2 

Vehicular Traffi c Only

This automatic gate operator is not designed nor 

is it intended for pedestrian traffi c. Vehicular gate 

operators must by their nature be powerful to 

function reliably. This power can cause injury or 

death. Accordingly, direct all pedestrian traffi c to 

a separate walk-through gate.

2.3 

Install This Gate Operator Only When:

a.  The operator is appropriate for the 

construction of the gate and the usage Class 

of the gate,

b.  All openings of a horizontal slide gate are 

guarded or screened from the bottom of the 

gate to a minimum of 1.83 m (6 ft) above the 

ground to prevent a 57.2 mm (2-1/4 inch) 

diameter sphere from passing through the 

openings anywhere in the gate, and the 

portion of the adjacent fence that the gate 

covers in the open position,

c. All exposed pinch points are eliminated or 

guarded, and

d.  Guarding is supplied for exposed rollers.
e.  When utilizing a Nice 936 board and  1050 

board and 8 sensors may be connected. 

2.4 

The operator is intended for installation only 

on gates used for vehicles. Pedestrians must 

be supplied with a separate access opening. 

The pedestrian access opening shall be 

designed to promote pedestrian usage. 

Locate the gate such that persons will not 

come in contact with the vehicular gate during 

the entire path of travel of the vehicular gate.

2.5 

The gate must be installed in a location so 

that enough clearance is supplied between 

the gate and adjacent structures when 

opening and closing to reduce entrapment 

risk. Swinging gates shall not open into public 

access areas

2.6 

The gate must be properly installed and work 

freely in both directions prior to gate operator 

installation. Do not ochange operator settings  

to compensate for an improperly installed, 

improperly functioning, or damaged gate.

2.7 

Permanently mounted controls intended for 

user activation must be located at least 1.83 

m (6 ft) away from any moving part of the gate 

and where the user is prevented from reaching 

over, under, around or through the gate to 

operate the controls. Exception: Emergency 

access controls only accessible by authorized 

personnel (e.g. fire, police, EMS) may be 

placed at any location in the line-of-sight of 

the gate.

2.8 

The Stop and/or Reset button must be located 

in the line-of-sight of the gate. Activation of 

the reset control shall not cause the operator 

to start.

2.9 

A minimum of two (2) WARNING SIGNS shall 

be installed, in the area of the gate. Each 

placard is to be visible by persons located 

on the side of the gate on which the placard 

is installed.

2.10 

For gate operators utilizing a non-contact 

sensor (Photo Eye):

a.  See instructions on the placement of non-

contact sensors for each Type of application,

b.  Care shall be exercised to reduce the risk 

of nuisance tripping, such as when a vehicle, 

trips the sensor while the gate is still moving, 

and

c.   One or more non-contact sensors shall 

be located where the risk of entrapment or 

obstruction exists, such as the perimeter 

reachable by a moving gate or barrier.

Содержание TITAN12L

Страница 1: ...Actuator Vehicular Swing Gate Actuator TITAN12L 936 Control Board TITAN12L1 1050 Control Board CBOX with 1050 control board CBOX with 936 control board 912L Programming controls connections and safet...

Страница 2: ......

Страница 3: ...al Release Handle 20 FIGURE 10 9 Wire Harness Insertion 20 FIGURE 10 10 TITAN12L 12L1 Actuator Wiring 20 10 6 936 Control Board Wiring 21 10 6 1 TITAN ACTUATOR WIRING PULL TO OPEN 21 10 6 2 TITAN ACTU...

Страница 4: ...AN12L 12L1 gives dealers installers and homeowners the ability to take control of their access and security systems This actuator includes a 2 year factory warranty against manufacturing defects and l...

Страница 5: ...input and the solar charge input All settings are stored in non volatile memory that is protected from power outages Programmable slowdown position Built in current sensing provides inherent gate forc...

Страница 6: ...g or locking the gate Gate opening and closing speed acceleration soft start settings and reversing speed may be set to factory default settings or individually programmed per customized gate installa...

Страница 7: ...security and reliable operation it is essential these components operate together as a system It is the responsibility of the system designer and or installer to ensure any safety or operational issue...

Страница 8: ...four single family dwellings 2 1 2 Class II Commercial General Access Gate Operator Intended for use in a commercial location or building such as a multi family housing units ve or more single family...

Страница 9: ...is supplied between the gate and adjacent structures when opening and closing to reduce entrapment risk Swinging gates shall not open into public access areas 2 6 The gate must be properly installed a...

Страница 10: ...hicle detectors but should be wired accordingly 4 Gate Construction and Safety Gate construction plays a very important role in ensuring the safety of any automated gate system The standard for gate c...

Страница 11: ...in the gate and in that portion of the adjacent fence that the gate covers in the open position The gate panel shall include the entire section of the moving gate including any back frame or counterba...

Страница 12: ...ned constructed and installed in accordance with security related parameters speci c to the application in question 5 Maintenance of Gate Systems To keep your automated gate system performing both saf...

Страница 13: ...ing gate and the ground is greater than 4 in 101 6 mm and less than 16 in 406 mm or b The distance between the center line of the pivot and the end of the wall pillar or column to which it is mounted...

Страница 14: ...lose direction provided the gate in the open direction presents no risk of entrapment Slide Gates One sensor in the Open direction and one sensor in the Close direction The gate operator tests for the...

Страница 15: ...WINDOW PROGRAM MENU CONTROL BUTTONS GATE OPERATION CONTROL BUTTONS ACCESSORY POWER OUTPUTS OUTPUTS POWER INPUT CONNECTIONS MOTOR CONTROLS 30A EARTH GROUND CONNECTION ACCESSORY POWER OUTPUTS and PROGRA...

Страница 16: ...OTOR SERIES 1050 MOTOR 2 BATTERY SOLAR P OXI A Receiver UL325 Compliant Monitored Safety Devices s required Accessory Output Connections Power Input Connections Motor Output Connections BlueBus Connec...

Страница 17: ...eometry and rate of speed of the gate it is critical that the measurements below are followed The pivot arm may need to be cut to achieve the correct placement of the actuator mounting hole Measuremen...

Страница 18: ...The pivot arm may need to be cut to achieve the correct placement of the actuator mounting hole Measurements are taken from the center of pivot of the gate hinge DIRECTION OF OPENING GATES CLOSED HING...

Страница 19: ...al operation is possible NOTE Manual operation may be prevented if the actuator is fully retracted FIGURE 10 6 MANUAL RELEASE DISENGAGE FIGURE 10 7 MANUAL RELEASE RE ENGAGE MANUAL RELEASE RE ENGAGE 1...

Страница 20: ...om of the actuator loosen the strain relief nut and insert the wire into the actuator housing The connections are on the top of the actuator behind the limit assembly Terminal block for harness connec...

Страница 21: ...e actuator with the shorter cable must plug into Motor 1 connections 10 6 2 TITAN ACTUATOR WIRING PUSH TO OPEN 10 6 1 TITAN ACTUATOR WIRING PULL TO OPEN 10 INSTALLATION PROCEDURES CONT GREEN ORANGE BL...

Страница 22: ...or a dual leaf swing gate installation For dual actuators the actuator with the shorter cable must plug into Motor 1 connections 10 7 2 TITAN ACTUATOR WIRING PUSH TO OPEN 10 7 1 TITAN ACTUATOR WIRING...

Страница 23: ...ked Limit 1 Open or Limit 2 Open if using motor 2 illuminate red indicating the open limit is active for a pull to open ii The LED marked Limit 1 Close or Limit 2 Close if using motor 2 illuminate red...

Страница 24: ...ELLS Possible Entrapment Zones Typical Installation Diagram Utilizing Photocells Safety Loop for vehicle Detection Only Safety Loop for vehicle Detection Only 4 Min from closed gate Loop Shadow Loop E...

Страница 25: ...ment protection DURING INSTALLATION DISCONNECT POWER at the control panel before making any electric service power connection Be aware of all moving parts and avoid close proximity to any pinch points...

Страница 26: ...nt is required to ensure continuous functionality safety and to ensure reliable operation in all weather conditions Inspect electrical assemblies and wiring installations for damage general condition...

Страница 27: ...r Adjust Force Settings Check the input LEDs Any ON will hold the gate open and indicates a problem with a keying device Check the external entrapment devices Any activated devices will hold the gate...

Страница 28: ...d in each direction Appears when Swing gate operator does not have at least one entrap ment sensor programmed and installed for both open and close direction for travel Appears when previously learned...

Страница 29: ...ting the force or the limit of travel retest the gate operator Failure to adjust and retest the gate operator properly can increase the risk of injury or death 4 V ri ez le fonctionnement de l ouvre b...

Страница 30: ...rian usage Locate the gate such that persons will not come in contact with the vehicular gate during the entire path of travel of the vehicular gate L ouvre barri re est destin n tre install que sur d...

Страница 31: ...la barri re Chaque tiquette doit tre visible des personnes situ es de chaque c t de la barri re sur laquelle l tiquette est install e For gate operators utilizing a non contact sensor Pour les ouvre...

Страница 32: ...adiofr quence RF l ouvre barri re pour pr venir le coincement doit tre situ un endroit o la transmission des signaux ne sera pas obstru e ou g n e par des structures des arbres ou d autres obstacles s...

Страница 33: ...www hysecurity com 33...

Страница 34: ...34 www hysecurity com...

Страница 35: ...www hysecurity com 35...

Страница 36: ...36 www hysecurity com Contact us Nice 6705 S 209th St Suite 101 Kent WA 98032 2327 Ph 1 253 867 3700 Fax 1 253 867 3702 www hysecurity com www facebook com hsgateoperators...

Отзывы: