COMMON FUNCTIONS

Name

This parameter enables the user to assign the automation with a name other than the original, to facilitate identification (e.g. northern gate).
A name comprising maximum 24 characters, including spaces, is admitted.

Series

This parameter can be set with a value from 0 to 63; the factory setting is “0”.
The series is a number that has to be assigned to each gearmotor, receiver or other device potentially connectable on a BusT4 network, to define its “clas-
sification area”. Subsequently, when using automations in a complex system, all devices with the same series number can be controlled simultaneously.

Address

This parameter can be set with a value from 1 to 128; the factory setting is “2” for Receivers and 3 for Control Units.
The address is a number that has to be assigned to each gearmotor, receiver or other device potentially connectable on a BusT4 network, to distinguish it 
from other devices in a series. Therefore all devices within a series must have a different address from one another.

Group

This parameter can be set with a value from 1 to 14, or “None”; the factory setting is “None”.
The function enables the user to assign a number to a device to be controlled (for example a gearmotor or other device potentially connectable to a BusT4 
network), which enables this device to belong to a specific “command group”.
Several devices, even if they belong to different series, can form part of the same group. Up to 14 groups of devices can be created and, in particular, the 
same device may be inserted in 4 different groups.
In a device network, use of this function enables:
- simultaneous control of different devices inserted in a group, even if some of these belong to different series;
- use of a single receiver, installed in one of the devices belonging to the group, to control all the devices belonging to the group.

Firmware version (not modifiable)

This function enables the display of the version of the firmware present in a device.

Hardware version (not modifiable)

This function enables the display of the version of the hardware present in a device.

Serial number (not modifiable)

This function enables the display of the serial number identifying a specific device. This number is different for each device, even if of the same model.

Password management:

This function is useful to restrict access by unauthorised personnel to all or some of the programming functions of a device. If a device is password protected, 
the user must perform the “log in” procedure to proceed with a programming session, followed by the “log out” procedure on completion of the programming 
procedure. Note – the “log out” procedure enables the user to prevent access by unauthorised personnel, by re-activating the existing password. 

Caution! 

– In programming the password on multiple devices (for example, on the Oview, control unit, receiver, etc.), it is advisable to use the same password for all 
devices, including the Oview. This will avoid the need to repeat the login procedure each time the device is changed during use of Oview and the connected 
Software.
Two types of password can be programmed on the devices (including Oview).
- the user password, containing 6 alphanumeric characters maximum. 

Caution!  – Do not use uppercase letters.

- the installer password, containing 6 alphanumeric characters maximum. 

Caution! – Do not use uppercase letters.

CONTROL UNIT FUNCTIONS

Installation

Bluebus search (0x0a)

This function enables start-up of the procedure for learning the devices connected to the Bluebus input and the HALT input of the control unit of an automa-
tion. Important – To activate the device search, press “Start”.

Position programming

• reverse rotation (0xa3)

This parameter type is ON/OFF; the factory setting is “OFF” (standard motor rotation). This function 
reverses the rotation direction of the encoder to align it with the direction of the motor; the factory setting is “OFF” (standard rotation direction of the encoder). 
Important – When you modify this parameter, you must then run the open/close position learning procedure.

• open (0x18)

This function is expressed in encoder pulses. During an opening manoeuvre, this enables programming of the precise point (position) of the door opening 
travel limit. To do so, use the hold-to-run ”open” and ”close” buttons; this enables you to determine the desired position and save it with the “OK” button. If 
the motor has a mechanical limit switch, the position is not displayed.

• open deceleration (inverters only) (0x24)

This function is expressed in encoder pulses. During the opening manoeuvre this enables programming of the precise point (position) at which the door should 
start decelerating before reaching the limit switch. To do so, use the hold-to-run ”open” and ”close” buttons; this enables you to determine the desired posi-
tion and save it with the “OK” button.

• partial open 1 (0x1b)

This function is expressed in encoder pulses. During the opening manoeuvre this enables programming of the precise point (position) at which the door stops 
travel (partial open). To do so, use the hold-to-run ”open” and ”close” buttons; this enables you to determine the desired position and save it with the “OK” 
button. If the motor has a mechanical limit switch, the position is not displayed, but the closing time is displayed instead.

• partial open 2 (0x1c)

This function is expressed in encoder pulses. During the opening manoeuvre this enables programming of the precise point (position) at which the door stops 
travel (partial open). To do so, use the hold-to-run ”open” and ”close” buttons; this enables you to determine the desired position and save it with the “OK” 
button. If the motor has a mechanical limit switch, the position is not displayed, but the closing time is displayed instead.

Содержание NDA001

Страница 1: ...Programmable functions using the Oview programmer NDA001 STF NDA001 Rev00 Firmware DA02...

Страница 2: ...on In programming the password on multiple devices for example on the Oview control unit receiver etc it is advisable to use the same password for all devices including the Oview This will avoid the n...

Страница 3: ...action doors 0x7C deletes all data in the control unit memory except for the reserved parameters series address hardware version software version serial number It also loads the default values for fas...

Страница 4: ...g light is switched on at the same time as the start of the manoeuvre time in opening 0x95 This parameter is expressed in seconds and can be set with a value from 0 to 10 sec the factory setting is 3...

Страница 5: ...ciable with inputs 1 2 3 present on the control unit of an automation The commands available for each input are described in Table 1 while the command categories and relative operating modes are descr...

Страница 6: ...e When this command is sent the control unit acti vates the application to complete the next manoeu vre following the previous one or still in progress according to the sequence of manoeuvres as en vi...

Страница 7: ...ng Program the required operating mode apartment block 1 open command configuration opening operating mode apartment block 1 open When this command is sent the control unit acti vates the application...

Страница 8: ...MODE DESCRIPTION Open stop close stop Operating mode set in factory This executes the above sequence Open Stop Close Open This executes the above sequence Open Close Open Close This executes the abov...

Страница 9: ...Opening Caution During execution of the Opening ma noeuvre this command is ignored Stop When the control unit receives the command is stop the current Close ma noeuvre Caution During execution of the...

Страница 10: ...euvre in progress Stop and brief inversion When the control unit receives the command it stops the Closing manoeuvre in progress immediately and activates the application to perform a brief inver sion...

Страница 11: ...vated and all others remain off The function uses outputs OUT TL1 OUT TL2 and OUT TL3 at 24V 5W sca 0x01 The programmed light indicates the operating status of the control unit light off application i...

Страница 12: ...ue to having been previously memo rised with a command when the channel is activated by the transmitter the control unit only activates the programmed output and ignores the motor command The OUT TL3...

Страница 13: ...ut active 24 dc max 10 VA suction cup 1 With this function programmed the suction cup is activated when the appli cation is in the maximum Closing position Note The suction cup is disabled in all othe...

Страница 14: ...setting is 2 sec This function enables programming on the Control unit of the required time interval to pass between the end of a Closing manoeuvre and the start of an Opening manoeuvre suction cup t...

Страница 15: ...eating the motor when the ambient temperature is below 5 C Reserved 1 0xaa This parameter accesses the inverter overcurrent controls To modify this setting contact Nice technical service Reserved 2 0x...

Страница 16: ...hort circuit on output 1 or on the courtesy light of the control unit Out 2 overload Indicates an electrical overload or shortcircuit at output 2 M1 low overtravel Indicates that the absolute encoder...

Страница 17: ...d the correct memorisation in the control unit CMD 3 Indicates whether the control photocell is present the relative operating status and the correct memorisation in the control unit CMD 4 Indicates w...

Страница 18: ...iew desktop software is used together with the O view programmer with bluetooth module User permits This function enables the installer to decide which functions and parameters are to be selected for...

Отзывы: