background image

How to connect IP video cameras

Smartphone pairing

Up to 4 IP video cameras can be connected to the control unit, 

through  the  domestic  Wi-Fi  network  (only  control  units  connected 

in Client mode).

Access the Device programming menu - IP video cameras

Enter the user name and password of the IP video camera, the AD-

DRESS LINK and the MAC ADDRESS then set the reception interval 

of the frames from 1 to 5 seconds and the number of frames...

Before proceeding make sure you have disabled the user in 

the section

Download the MyNice World app to the smartphone 

• if the control unit is connected in Client mode, ensure that the 

smartphone is connected to the Wi-Fi or is nonetheless enabled to 

exchange data;

•  if the control unit is connected in Access Point mode, connect the 

smartphone to the WLAN of the control unit.

Access the menu 

Start the MyNice World app and configure the system (New 

configuration)

Fill in the fields

 by copying the IP address of the control unit and 

the serial number.

Enter the user name exactly as it is memorised in the control 

unit and the respective PIN, press Start on the control unit 

and OK on the smartphone.

 Wait for the pairing procedure to ter-

minate, as confirmed by an acoustic signal. To confirm the correct 

pairing, the name of the user who requested the authentication will 

appear on the control unit.

19

User management

ENABLE DIRECT MANAGEMENT VIA APP

        Settings Menu

Smartphone Association

Содержание MNCUC

Страница 1: ...Nice MNCUT MNCUTC MNCUC EN Instructions and warnings for installation and use MyNice control unit...

Страница 2: ......

Страница 3: ...rdy Do not place the system s components close to sources of strong heat as this may damage them Each sensor has its own operating principle check the suitability of the intended positioning against t...

Страница 4: ...aining from 1 to 99 detectors Depending on the type and size of the system there are 3 control unit models to choose from MNCUT MyNice control unit 99 zones in 6 areas dual band two way radio with 7 c...

Страница 5: ...h screen good visibility can be obtained even at 35 Technical characteristics Current draw Table 1 Code MNCUT MNCUTC MNCUC Power supply 110 V 240 V 110 V 240 V 110 V 240 V Surveillance 18 18 18 Radio...

Страница 6: ...l unit after carefully considering the following aspects the control unit without the display must be positioned at least 1 metre above the floor to favour the Wi Fi communication Place the versions w...

Страница 7: ...in the outdoor area subsequently activating the siren at full power and making phone calls in case of attempted break ins involving the inner areas Example of block subdivision Fig 3 Area 1 Garden de...

Страница 8: ...5 The electrical connections 6 The installation of the control unit see Installing the control unit Since the system components communicate via radio it is advisable to first configure the system on a...

Страница 9: ...1 3 5 6 4 5 2 1 2 3 4 7 5 mm 5 mm 9 1 2...

Страница 10: ...reply with 1 beep Interruption of alarm calls Enter the indicated codes and wait for the reply the control unit will reply with the recorded voice messages or if none are recorded with acoustic signal...

Страница 11: ...rom any telephone number by entering after the reply signal the User PIN code followed by If the voice messages have been recorded correctly the control unit will reply with the following voice messag...

Страница 12: ...y detectors sirens equipped with the appropriate input The fault input if used triggers the ANOMALY signal and the rela tive warning messages All unused inputs may be left without any connection they...

Страница 13: ...alarm inputs alarm inputs tamper inputs only with inputs used in NC mode Warning Not conforming to EN 50131 close on GND R22k balanced fault input EN 50131 close on GND 12 V for supplementary sirens g...

Страница 14: ...tdoors with voice messages and LED flashing light MNSC Wired siren for outdoors with voice messages and LED flashing light for MNCUTC and MNCUC only MNSI Two way dual band radio siren for indoors with...

Страница 15: ...stance or physical obstacles lying in between the radio range between the control unit and certain devices must be extended The repeater must be placed at an equal distance from the control unit and f...

Страница 16: ...ge 2 of the sirens Specific parameters of MNMC and MNGB magnetic contact detectors Door open signal normally enabled EN 50131 but can be disa bled If active it signals any open doors windows when the...

Страница 17: ...It is obtained by adding 1 to the last digit of the PIN for example PIN 11111 duress function activation code 11112 or PIN 11119 duress function activation code 11110 In case of error calls can be dis...

Страница 18: ...aid panic and aggression aid GSM calls periodic messages Internet connection Contact ID digital protocols Other communication parameters To activate and manage reception of alerts via e mail Email To...

Страница 19: ...hat the smartphone is connected to the Wi Fi or is nonetheless enabled to exchange data if the control unit is connected in Access Point mode connect the smartphone to the WLAN of the control unit Acc...

Страница 20: ...IS0602A01EN_22 12 2017 www niceforyou com Nice S p A Via Pezza Alta 13 31046 Oderzo TV Italy info niceforyou com...

Отзывы: