TECHNICAL FEATURES OF THE UNIT:
Power
: 230 Vac ± 20%, 50 Hz
Maximum actuator power
: two
1
/
2
Hp motors with capacitor, max 20 µF
Maximum flashing light power
: 100 W at 230 Vac ( the output has a fixed voltage)
Max current accessories, 24 Vac
: 200 mA
Max current phototest output
: 100 mA
Gate open indicator max. power
: 2 W (24 Vac)
Max electric lock power
: 25 W (12 Vac)
Working time
: from 2.5 to 40 sec. (from 30 to 80 sec. with TLM)
Pause time
: from 5 to 80 sec.
TRA opening delay time
: 0 or from 2.5 to 12 sec. (1st motor starting delay in opening)
TRC closing delay time
: 0 or from 2.5 to 12 sec. (2nd motor starting delay in closing)
Force adjustment
: from 0 to 100% in version A6; 30-45-60-80-100% in versions A6F and A700F
Operating temperature
: -20 ÷ 70 °C
Size
: 280 x 220 x 110
Weight
: approx. 2.7 Kg
Protection level
: IP 55
Nice s.r.l. reserves the right to modify its products at any time without prior notice.
English
34
FINAL NOTES:
This manual is for use only by technical personnel qualified to carry out the installation.
• No information given in this manual can be considered of any interest to the end user!
• No settings or adjustments contained in this manual can be carried out by the end user!
✓
Once the plant is finished inform the end user, in detail also in writing, how to use the automatic gate, about residual hazards
and about how to use the manual unlock device in the event of a power cut.
✓
Inform the owner of the plant about the need for a regular and accurate maintenance, especially regarding a regular check
of the safety and torque limiting devices.