10) Servicing:
The card, being electronic, needs no particular maintenance.
However, make sure the device that controls the motor overload cut-
out is in perfect working order and well adjusted at least twice a year;
adjust with the trimmer if necessary.
Check the safety devices (photoelectric cells, pneumatic edges, etc.)
and the flashing light are in perfect working order
10.1) Information on environmental protection measures:
This product is made from various kinds of material, some of which
can be recycled.
Recycle or dispose of the product in compliance with current laws
and by-laws.
10.2) Technical features of the control unit:
Mains power
: 400 Vac or 230 Vac ± 10%, 50 or 60Hz
Max. current to motors
: 4A
Auxiliaries output
: 24Vac, max. current 200mA (400mA if Phototest is not used)
Phototest output
: 24Vac, max. current 200mA
Flashing light output
: For 230Vac flashing lights, max. power 40 W
Gate open Light output “SCA”
: For Light 24Vac, max. power 2 W
Working time
: Adjustable from <3 to>120 s, or from <90 to>210 s with TLM
Pause time
: Adjustable from <5 to>200 s
Operating Temperature
: -20 ÷ 70 °C