STEP - BY STEP

SCA  24Vac

common

M1

Phototest

Services

STOP

PHOTO 

OPEN

Constant resistance 

STOP 8.2K

 

(sensitive edge)

F2

14

9

CLOSE

COMMON

OPEN

7

6

8

24V

0

10

24V

11 12 13

15

17

16

19

18

20

TL

21

22

TP

OK

AERIAL

Radio
receiver

FCA

Flashing light

OVERHEAD
GARAGE DOOR

SLIDING GATE

{

{

2.3.1) Wiring diagram

Terminal

Functions

Description

1-2

Power supply

mains power supply line

3-4

Flashing light

Output for connecting flashing light to mains voltage (Max. 100W)

5-6 

Courtesy Light

Output for connection of a mains voltage lamp (Max 100W)

7-8-9

motor

motor output (Max 500VA)

10-11

24 Vac

24 Vac services power supply: Photo, Radio, ecc. (Max. 200mA)

12

Phototest

Phototest output: power supply to photocell transmitters (Max. 100 mA)

13

Common

Common for all inputs

14

A.C. Light

24 Vac output for open gate indicator light (Max. 2W)

15

OPEN limit switch

Input for connection of the OPEN limit switch.

16

CLOSE limit switch

Input for connection of the CLOSE limit switches.

(15-16)

Stop

The “Stop” input is obtained by connecting an NC-type contact serially with the limit switches
(see wiring diagram).

17

Photo

Input for safety devices with NC contact (e.g. photocells)

18 

Step-by-step

Input for cyclic command (OPEN – STOP – CLOSE – STOP)

19

Open

Input for opening function (OPEN – STOP – OPEN)

20

Close

input for closing command (CLOSE – STOP – CLOSE)

21-22

constant resistance Stop

Input for “constant resistance Stop” 8.2k

(e.g. sensitive edge)

2.3.2) Description of the connections

The following table provides a brief description of the possible control unit output connections.

Содержание Mindy A100F

Страница 1: ...ra mindy A100F Istruzioni ed avvertenze per l installatore Instructions and warnings for the fitter Instructions et recommandations pour l installateur Anweisungen und Hinweise f r den Installateur In...

Страница 2: ...nstallation This brochure which contains important directions regarding system safety should be saved for future reference along with the technical instructions for the automatic system mindy A100F Co...

Страница 3: ...the electronic board from accidental contacts see figure 1a The electronic board can be interfered with only in the event of real need in this case proceed as shown in figure 1b 2 Installation Automa...

Страница 4: ...s of the Normally Open NA contacts are not used they should be left free If there is more than one NA contact on the same input they must be connected in PARALLEL The contacts must be mechanical and p...

Страница 5: ...ax 200mA 12 Phototest Phototest output power supply to photocell transmitters Max 100 mA 13 Common Common for all inputs 14 A C Light 24 Vac output for open gate indicator light Max 2W 15 OPEN limit s...

Страница 6: ...nnected to each other in parallel with an 8 2K termination resistance Note 2 The NO and NC combination can be obtained by placing the two contacts in parallel and placing in series to the NC contact a...

Страница 7: ...ntrol unit terminals 17 18 Set Dip Switch 10 to ON Phototest enabled in the future it can be disabled at any time by setting Dip Switch no 10 to OFF Pho totest disabled When using 2 pairs of photocell...

Страница 8: ...ic movement stops immediately and briefly reverses direction after the device connected to the input is triggered Repeat this test for the closing manoeuvre The OK LED located in the centre of the boa...

Страница 9: ...ement stops as soon as the input command stops During an opening manoeuvre movement will stop when the limit switch is trig gered during a closing manoeuvre movement will stop if the Pho tocell or the...

Страница 10: ...eached In the Automatic operating mode an opening manoeuvre is followed by a pause after which the gate closes automatically The Always Close function comes into play following a power failure if the...

Страница 11: ...imit switch the duration of the deceleration stage will be proportional to the Work ing Time for proper operation of the deceleration feature we recommend the installation of the limit switches During...

Страница 12: ...ode Use two motors with the control units connected as indicated in fig 5 Connect the flashing light end the Gate Open Indicator to any one of the two control units setting up the connections as shown...

Страница 13: ...he connection of the constant resistance STOP input the manoeuvre is enabled only if there is a voltage of 9 to 11 Vdc corre sponding to a resistance of 6150 to 10250 on terminals 21 22 The gate chang...

Отзывы: