GB
3
The A100F control unit enables the control of overhead garage
doors and sliding gates equipped with single-phase alternate-cur-
rent gearmotors. It features a system for force adjustment and a
“constant resistance STOP” input (e.g. for sensitive edges).
The control unit features a number of functions that can be selected
using dip-switches (mini selector switches); some adjustments can
be made using trimmers, while a jumper enables the selection of the
type of automation: “Sliding / Overhead”.
A number of LEDs located near the inputs signal their status, while
an additional LED located below the dip-switch (OK LED) signals the
correct operation of the internal logic.
1) Product description
2.1) Mounting the A100F control unit
• Mount the control unit on a non-movable, flat vertical surface suit-
ably protected from impacts. Make sure that the bottom is at least
40cm off the ground.
• Insert the cable or tube leads through the bottom of the container
only (see
figure 1a
).
• The container is provided with a cover designed to protect the
electronic board from accidental contacts (see
figure 1a
).
The electronic board can be interfered with only in the event of real
need; in this case, proceed as shown in
figure 1b
.
2) Installation
Automatic gate and door systems may only be installed
by qualified fitters in the full respect of the law.
Comply with the warnings shown in the “Warnings for fit-
ters” file.
If you need to replace a fuse, be careful to use one of the same type and having identical characteristics:
Dimensions (5x20), rated current (e.g. 5A), blowout characteristics (T=delayed, F=quick), maximum voltage and break-
ing capacity.
!
!
TL
A
B
C
D
E
F
G
H
I
L
M
N
O
P
S
Q
R
T
U
V
Z
A
Transformer
B
“Common” relay
C
“Brake” relay
D
Microprocessor
E
SMX Radio connector
F
Low voltage fuse
G
“Open/Close” relay
H
“Pickup” relay
I
“Courtesy light” relay
L
Line fuse
M
Force selector switch (F)
N
Power supply terminal board
O
Flashing / C.tsy light / motor power
supply output terminal board
P
Input / output control terminal board
Q
Working Time adjustment trimmer (TL)
R
Led OK
S
Function selection Dip-Switch
T
Pause Time adjustment trimmer (TP)
U
STOP input terminal board with constant
resistance 8.2K
Ω
(sensitive edge)
V
Selection jumper: overhead / sliding
Z
Aerial terminal board
1a
1b