Switch 1-2: 

Off-Off

= “Manual” movement, i.e. hand operated

On -Off

= “Semiautomatic” movement

Off-On

= “Automatic” movement, i.e. automatic closing

On -On

= “Aut always close” movement

Switch 3:

On

= Condominium operation ( not available in manual mode)

Switch 4:

On

= Pre-flashing

Switch 5: 

On

= Close 5” after Photo (in automatic mode) or Close after Photo (in semiautomatic mode)

Switch 6:

On

= “Photo” safety also during opening manoeuvres

Switch 7:

On

= gradual departure

Switch 8:

On

= deceleration

Switch 9:

On

= Brake

Switch 10 

On

= Phototest

Ponticello

= overhead garage door

Ponticello

= sliding gate

6) Programmable functions

The control unit features a set of microswitches and a selection
jumper that allow you to activate various functions designed to make
the system more suitable to the needs of users and more reliable
under different operating conditions. These functions are enabled by
setting the relevant dip-switch to ON; if the dip-switch is set to OFF
they are disabled.

Some of the programmable functions are linked to

safety aspects; carefully evaluate the effects of a function

and see which function will ensure the highest possible

level of safety.

The dip-switches allow you to select the various operating modes
and to activate the desired functions according to the table below:

1

10

!

6.1) Description of functions

Here is a brief description of the functions that can be added by setting the corresponding Dip-Switch to “ON”.

Switch 1-2: 

Off-Off

= “Manual” movement (hand operated)

On-Off

= “Semiautomatic” movement

Off-On 

= “Automatic” movement (automatic closing)

On-On 

= “Aut Always Close” movement

In the “Manual” operating mode, the gate will only move as long as the control button is held down.
In “Semiautomatic” mode, a command impulse will perform the whole movement until the Working Time limit expires or the limit stop is
reached. In the “Automatic” operating mode, an opening manoeuvre is followed by a pause, after which the gate closes automatically.
The “Always Close” function comes into play following a power failure; if the gate is not closed (FCC), a closing manoeuvre takes place, auto-
matically preceded by 5 seconds of pre-flashing.

Switch 3:

On

= Condominium operating mode (not available in the Manual mode)

In the Condominium operating mode, once an opening manoeuvre has started it cannot be interrupted by other command pulses on “STEP-
BY-STEP” or “OPEN” until the gate has finished opening.
During a closing manoeuvre, a new command pulse will stop the gate and reverse the direction of movement in order to open the gate.

Switch 4:

On

= Pre-flashing

A command impulse activates the flashing lamp followed by movement 5 s later (2 s later in the manual mode).

Switch 5:

On

= “Close” 5 s. after Photo (in the “Automatic” mode) or “Close” after Photo (in the “Semiautomatic” mode)

This function, if in the Automatic mode, allows the gate to be kept open only for the time required for transit; when “PHOTO” finishes, the
manoeuvre stops. After 5 s a closing manoeuvre will automatically begin. In the Semiautomatic mode, the triggering of PHOTO during a clos-
ing manoeuvre will cause the re-opening of the gate followed by its automatic closing with adjusted pause time.

Switch 6:

On

= Safety (Photo1) also during the opening manoeuvre

The “Photo” safety device is normally active only during the closing manoeuvre; if Dip-Switch 6 is turned "On", the safety device will cause
the movement to stop also during the opening manoeuvre.
In the Semiautomatic or Automatic modes, the opening manoeuvre will start again immediately after the photocell has been disengaged.

Switch 7:

On 

= gradual departure

Starts the manoeuvre gradually, preventing the automatic system from being jolted. 

Switch 8:

On 

= deceleration 

Deceleration reduces speed to 30% of rated speed in order to limit the force of the impact in the gate’s opening and closing areas.

overhead garage door

sliding gate

Содержание Mindy A100F

Страница 1: ...ra mindy A100F Istruzioni ed avvertenze per l installatore Instructions and warnings for the fitter Instructions et recommandations pour l installateur Anweisungen und Hinweise f r den Installateur In...

Страница 2: ...nstallation This brochure which contains important directions regarding system safety should be saved for future reference along with the technical instructions for the automatic system mindy A100F Co...

Страница 3: ...the electronic board from accidental contacts see figure 1a The electronic board can be interfered with only in the event of real need in this case proceed as shown in figure 1b 2 Installation Automa...

Страница 4: ...s of the Normally Open NA contacts are not used they should be left free If there is more than one NA contact on the same input they must be connected in PARALLEL The contacts must be mechanical and p...

Страница 5: ...ax 200mA 12 Phototest Phototest output power supply to photocell transmitters Max 100 mA 13 Common Common for all inputs 14 A C Light 24 Vac output for open gate indicator light Max 2W 15 OPEN limit s...

Страница 6: ...nnected to each other in parallel with an 8 2K termination resistance Note 2 The NO and NC combination can be obtained by placing the two contacts in parallel and placing in series to the NC contact a...

Страница 7: ...ntrol unit terminals 17 18 Set Dip Switch 10 to ON Phototest enabled in the future it can be disabled at any time by setting Dip Switch no 10 to OFF Pho totest disabled When using 2 pairs of photocell...

Страница 8: ...ic movement stops immediately and briefly reverses direction after the device connected to the input is triggered Repeat this test for the closing manoeuvre The OK LED located in the centre of the boa...

Страница 9: ...ement stops as soon as the input command stops During an opening manoeuvre movement will stop when the limit switch is trig gered during a closing manoeuvre movement will stop if the Pho tocell or the...

Страница 10: ...eached In the Automatic operating mode an opening manoeuvre is followed by a pause after which the gate closes automatically The Always Close function comes into play following a power failure if the...

Страница 11: ...imit switch the duration of the deceleration stage will be proportional to the Work ing Time for proper operation of the deceleration feature we recommend the installation of the limit switches During...

Страница 12: ...ode Use two motors with the control units connected as indicated in fig 5 Connect the flashing light end the Gate Open Indicator to any one of the two control units setting up the connections as shown...

Страница 13: ...he connection of the constant resistance STOP input the manoeuvre is enabled only if there is a voltage of 9 to 11 Vdc corre sponding to a resistance of 6150 to 10250 on terminals 21 22 The gate chang...

Отзывы: