6) What to do if…

The manoeuvre does not start even by operating the T1

key on the card.

Make sure that the card is properly powered and that the fuse is not
blown. Between terminals 8 and 9 there must be mains voltage and
between terminals 10 and 11 you must read a continuous voltage of
approx. 24 Vdc.

No manoeuvres can be commanded and the led related to

the STOP input flashes rapidly.

It is possible that a short circuit has occurred and/or an overload on
the services output. The control unit has a fuse that automatically
resets, try switching off the power, wait a few seconds and switch it
on again.

The power supply voltages are correct, yet the manoeuvre

will not start

The Stop and Photo inputs must give their consent to activate the
manoeuvre: make sure that the LED corresponding to these inputs

are on. Make sure that dip-switches 3-4 correspond to the type of
input used. If it is a 8.2k

input the voltage between terminals 10-12

must be between 6Vdc and 18Vdc

You are unable to memorize a new transmitter.

Make sure that the type of transmitter is compatible with those
already stored in the memory. Switch the control unit off and then
back on, and check the flashing of the “radio LED” to see what type
of transmitters are already memorized. 

The type of transmitter to be memorized is correct, but

you are unable to memorize it

Make sure that the card's receiving circuit operates properly: use a
functioning transmitter. If the control unit correctly receives a radio
code which is not, however, stored in the memory, it signals this con-
dition with a flash of the “radio LED”. If you have already memorized
the maximum number of transmitters (254), this event is signalled by
6 flashes.

7) Technical characteristics

Electronic control unit

Power supply: 

230 Vac 50/60 Hz or 120Vac 50/60Hz depending on the version (see value

on label)
Maximum motor power: 

600W for 230 Vac version; 400W for 120 Vac version

Command signal voltage:

approx. 24Vdc

Services (terminals 8-9): 

voltage 24Vdc ±30%; max current 50mA

Stop input: 

configurable between NO, NC or 8.2k

+-25%

Working time:

programmable from 5 to 120 seconds

Pause time:

programmable from 1 to 120 seconds or excludable

Operating temperature:

-20 ÷ 50 °C

Dimensions / weight: 

128 x 112 x 43mm 350gr

IP protection class:

44

Radio receiver 

Frequency: 433.92 

MHz

Coding:

FLO (fixed code), FLOR (rolling code) SMILO (rolling code)

Maximum number of transmitters that can be memorized:

254

Nice S.p.a reserves the right to modify its products at any time it deems necessary.

EC Declaration of conformity 

EC Declaration of conformity with Directive 1999/5/EC 

NOTES: The content of the present declaration corresponds to the latest
available revision, before the printing of the present manual, - of the document
registered at the head offices of Nice S.p.a.. The original text of this manual
has been readapted for publishing reasons.

Number: 

241/A02

; Revision: 

0

The undersigned, Lauro Buoro, in the role of Managing Director, declares
under his sole responsibility, that the product: 

Manufacturer's name:

NICE s.p.a.

Address:

Via Pezza Alta 13, Z.I. Rustignè, 31046 Oderzo (TV) Italy

Type:

Control unit for single 230V ac motor.

Models:

A02

- Accessories:

Radio control series FLO, FLOR, Smilo

Conform with the requirements of the following EC directive:

• 1999/5/EC; DIRECTIVE 1999/5/EC OF THE EUROPEAN PARLIAMENT AND

COUNCIL of 9 March 1999 regarding radio equipment and telecommunica-
tions terminal equipment and the mutual recognition of their conformity.
According to the following harmonised standards: EN 300220-3
V1.1.1:2000, 

The product also complies with the requirements of the following EC directives,
as amended by Directive 93/68/EEC of the European Council of 22 July 1993: 

• 73/23/EEC; DIRECTIVE 73/23/EEC OF THE EUROPEAN COUNCIL of 19

February 1973 regarding the approximation of member state legislation relat-
ed to electrical material destined for use within specific voltage limits
According to the following harmonised standards: EN 60335-1:1994; EN
50366:2003, 
EN 60335-2-95:2001 (as applicable), EN 60335-2-97:2000 (as applicable),
EN 60335-2-103:2003 (as applicable), EN 60950-1:2001 (as applicable)

• 89/336/EEC; DIRECTIVE 89/336/EEC OF THE EUROPEAN COUNCIL of 3

May 1989, regarding the approximation of member state legislation related
to electromagnetic compatibility
According to the following standards: EN 301 489-1:2004; EN 301 489-
3:2002

Oderzo, 2 January 2006

Lauro Buoro

(Managing director)

Содержание MINDY A02

Страница 1: ...ed avvertenze per l installatore Instructions et recommandations pour l installateur Anweisungen und Hinweise f r den Installateur Instrucciones y advertencias para el instalador Instrukcje i ostrze e...

Страница 2: ...supply is disconnected To proceed with the installation secure the container as shown in fig ure 1 When you drill a hole in the container for installation and wiring take the necessary precautions to...

Страница 3: ...nal 10 is the common one Some of these inputs have functions that depend on the programmed settings STOP input This input is designated for the connection of safety devices such as sensitive edges The...

Страница 4: ...direction control Since in some cases the behaviour of the safety devices depends on the manoeuvre direction the correct connection of the motor must be ensured Turn the power off to the control unit...

Страница 5: ...ch the fac tory setting or after the memory has been cancelled is approximately 120 seconds The operating time can be modified from a minimum of 5 to a maximum of 120 seconds if required The programmi...

Страница 6: ...be associated with a key whereas the same command can be activat ed using different keys One space for each memorized key is occu pied in the memory To proceed with the memorization of the transmitter...

Страница 7: ...the management of the radio control codes The read and write functions alone can read and copy the entire contents of the mem ory of the control unit therefore also the parameters and configurations w...

Страница 8: ...onds Pause time programmable from 1 to 120 seconds or excludable Operating temperature 20 50 C Dimensions weight 128 x 112 x 43mm 350gr IP protection class 44 Radio receiver Frequency 433 92 MHz Codin...

Отзывы: