Warnings:

The MINDY A02 control unit has been designed for the control of a sin-
gle-phase asynchronous motor used for the automation of shutters,
overhead garage doors, gates, rolling shutters or awnings.
Any other use is improper and prohibited. The motors must be equipped

with electromechanical limit switches designed to limit their movement.
Keep in mind that these automation systems must be installed by qual-
ified personnel in compliance with current laws and regulations.

The Mindy A02 control unit enables the control of single-phase asynchronous motors powered by the electrical mains, with “COMMON” “OPEN”
“CLOSE” type connections. It is designed for the automation of shutters, overhead garage doors, gates, rolling shutters or awnings. The control
unit incorporates a radio receiver operating at a frequency of 433.92 MHz, which is compatible with the following types of transmitters:

The control unit is equipped with a number of inputs used to activate commands such as “step-by-step”, “open”, “close”, as well as signals
for the triggering of safety devices such as photocells or stop commands. The control unit can be connected to TTBUS systems.

1) Product description

2) Installation

The electrical systems and the automations must be

installed by qualified and experienced personnel in com-

pliance with current legislation. Before you proceed to

make any connections make sure that the mains power

supply is disconnected.

To proceed with the installation, secure the container as shown in fig-
ure 1. When you drill a hole in the container for installation and wiring,
take the necessary precautions to guarantee the required IP protec-
tion class. The wires must always be threaded from below.

!

1

T1

T2

C

FLASH

L

+24Vcc

N

P.P.

PHOTO

STOP

M

A

B

C

E

D

F

L

I

H

G

N

O

P

A

Line fuse (5A)

B

“close” relay

C

“open” relay

D

low voltage transformer

E

microprocessor

F

connector for SMU programmer

G

programming dip-switch

H

“radio” LED

I

“radio” pushbutton

L

“stop”, “photo” and “step-by-step” inputs LED

M

terminal for radio aerial

N

“step by step” pushbutton

O

low voltage input terminals

P

line, motor and flashing light connection terminals

Coding

TX Line

Transmitters

FLO

FLO

FLO1, FLO2, FLO4

VERY

VERY VE

NICE WAY

WM080G, WM240C (code C)

FLOR

FLOR

FLO1R, FLO2R, FLO4R

VERY

VERY VR

ERGO

ERGO1, ERGO4, ERGO6

PLANO

PLANO1, PLANO4, PLANO6, PLANOTIME

NICE WAY

TUTTA LA LINEA; WM080G, WM240C (code A or B)

SMILO

SMILO

SM2, SM4

NICE WAY

WM080G, WM240C (code D)

Table “A1”

As the type of coding is different, the first transmitter mem-
orized also determines the type of transmitters that may be
memorized later, see “code” in table A1. 
Up to 254 transmitters can be memorized.
The management of the radio transmitters is made easier
by the SMU, TTP or TTI programming units.
After each command, the motor is powered for the set
“working time” and programmed during the installation
stage. The limit switch incorporated in the motor stops the
movement when the desired position is reached. The
“pause time” can be programmed after which automatic
closure occurs.

Содержание MINDY A02

Страница 1: ...ed avvertenze per l installatore Instructions et recommandations pour l installateur Anweisungen und Hinweise f r den Installateur Instrucciones y advertencias para el instalador Instrukcje i ostrze e...

Страница 2: ...supply is disconnected To proceed with the installation secure the container as shown in fig ure 1 When you drill a hole in the container for installation and wiring take the necessary precautions to...

Страница 3: ...nal 10 is the common one Some of these inputs have functions that depend on the programmed settings STOP input This input is designated for the connection of safety devices such as sensitive edges The...

Страница 4: ...direction control Since in some cases the behaviour of the safety devices depends on the manoeuvre direction the correct connection of the motor must be ensured Turn the power off to the control unit...

Страница 5: ...ch the fac tory setting or after the memory has been cancelled is approximately 120 seconds The operating time can be modified from a minimum of 5 to a maximum of 120 seconds if required The programmi...

Страница 6: ...be associated with a key whereas the same command can be activat ed using different keys One space for each memorized key is occu pied in the memory To proceed with the memorization of the transmitter...

Страница 7: ...the management of the radio control codes The read and write functions alone can read and copy the entire contents of the mem ory of the control unit therefore also the parameters and configurations w...

Страница 8: ...onds Pause time programmable from 1 to 120 seconds or excludable Operating temperature 20 50 C Dimensions weight 128 x 112 x 43mm 350gr IP protection class 44 Radio receiver Frequency 433 92 MHz Codin...

Отзывы: