TABLE 12 - Fault log
01
Press and hold down the “
Set
” key for approx. 3 seconds;
SET
3 s
02
Release the key when LED “
L1
” starts flashing;
SET
L1
03
Press keys “
” or “
” to move from the flashing LED to L8 LED (“input LED”) for the “Fault log” parameter;
/
L8
04
Press and hold the “
Set
” key through to completion of point 06;
SET
05
Wait approx. 3 seconds until the LEDs representing the levels corresponding to the manoeuvres with faults illuminate.
The LED L1 indicates the result of the most recent manoeuvre while L8 indicates the eighth-to-last manoeuvre. If the
LED is on this means that a fault has occurred; if the LED is off, everything is normal;
3 s
06
Press keys “
” and “
” to select the required manoeuvre: the corresponding LED performs a number of flashes equal
to those normally performed by the flashing light;
+
07
Release the “
Set
” key.
SET
TABLE 13 - SMXI / SMXIS / OXI / OXIFM / OXIT / OXITFM in mode I or in mode II
Output no. 1
“S.S.” (Step by Step) command
Output no. 2
“Partial opening 1” command
Output no. 3
“Open” command
Output no. 4
“Close” command
TABLE 14 - OXI / OXIFM / OXIT / OXITFM in extended mode II
No.
Command
Description
1
Step by step
“S.S.” (Step by Step) command
2
Partial opening 1
“Partial opening 1” command
3
Open
“Open” command
4
Close
“Close” command
5
Stop
Stops manoeuvre
6
Apartment block Step by Step
Apartment block control
7
Step by Step high priority
Gives command even when automation is blocked or commands are in progress
8
Partial open 2
Partial open (Opening of leaf M2 to 1/2 of normal opening)
9
Partial open 3
Partial open (Opening of two leafs to 1/2 of normal opening)
10
Open and block automation
It causes an opening manoeuvre, after which the automation is blocked; the control unit accepts no further commands with the exception
of “Step by step high priority”, “Release” automation and (from Oview only) the commands “Release and close” and “Release and open”
11
Close and block automation
It causes a closure manoeuvre, after which the automation is blocked; the control unit accepts no further commands with the exception
of “Step by step high priority”, “Release” automation and (from Oview only) the commands “Release and close” and “Release and open”
12
Block automation
It causes the manoeuvre to stop and the automation to block; the control unit accepts no further commands with the exception of “Step
by step high priority”, “Release” au to mation and (from Oview only) the commands “Release and close” and “Release and open”
13
Release automation
It causes the automation to be released and normal operation to resume
14
Courtesy light timer on
The Courtesy light comes on with timed turning off
15
Courtesy light on-off
The Courtesy light turns on and off in step-by-step mode
when purchasing a new version.
Important!
– Local legislation may impose heavy fines in the event of illegal
disposal of this product.
Disposal of buffer battery (if present)
Important!
– Even if discharged, the batteries may contain pollutant substanc-
es and therefore must NEVER be disposed of in normal waste collection points.
Dispose of according to separate waste collection methods as envisaged by
current local standards.
TECHNICAL CHARACTERISTICS OF THE PRODUCT
WARNINGS
: • All technical characteristics stated refer to an ambient tempera-
ture of 20°C (±5°C). • Nice S.p.a reserves the right to modify the product at any
time while maintaining the same functionalities and intended use.
• MC824L power supply:
230 Vac (+10% -15%) 50/60 Hz
• MC824L/V1 power supply:
120 Vac (+10% -15%) 50/60 Hz
• Nominal power absorbed from mains:
100 W
• Power absorbed by control unit battery connector with “standby-All”
operation (including a receiver with SM type connector):
below 100 mW
• Flashing light output(*):
1 “LUCYB” type flashing light (12 V, 21 W lamp)
• Electric lock output(*):
1 max. 12 Vac max. 15 VA electric lock
• Gate open light output(*):
one 24 V max. 4 W lamp (output voltage may
vary between -30% and +50%, output may also control small relays)
• BLUEBUS output:
1 output with maximum load 15 Bluebus units (maxi-
mum 6 pairs of MOFB or MOFOB phot 2 pairs of MOFB or MOFOB
photocells assigned as Opening d max. 4 MOMB or MOTB control
devices
• STOP Input:
For normally closed, normally open or 8.2 k
Ω
constant resist-
ance contacts in self-learning mode (a change from the memorised state
prompts the “STOP” command)
• PP Input:
for normally open contacts (closure of the contact prompts the
Step by Step command)
• OPEN Input:
for normally open contacts (closure of the contact prompts the
OPEN command)
• CLOSE Input:
for normally open contacts (closure of the contact prompts
the CLOSE command)
• Radio connector:
SM connector for SMXI, OXI and OXIFM family receivers
• Radio AERIAL input:
50 Ω
for RG58 or similar type cable
• Programmable functions:
8 ON-OFF type functions and 8 adjustable
functions
• Functions in self-learning mode:
• Self-learning of devices connected to
the BlueBus output. • Self-learning of type of device connected to “STOP”